Skip to content

What are you looking for?


You may also like

GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy PackGE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy PackGE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack
GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack
GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack
GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack

GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack


Only 10 left - Selling fast

PRODUCT SKU : IC695CPK330

PRODUCT TYPE : Blank Slot Filler Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694ACC310 blank slot filler module is a protective accessory engineered for the GE Fanuc RX3i PACSystem. It ensures unused slots remain shielded from dust, debris, and accidental contact, while maintaining airflow and rack stability.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: RX3i PACSystem

  • Part Number: IC694ACC310

  • Product Type: Blank Slot Filler Module

  • Weight: 0.25 lbs (0.11 kg)

  • Compatibility: All RX3i CPUs

  • Supported Racks: Main rack, Expansion racks, Remote racks

  • Compatible Standard Baseplates: 7-slot, 12-slot, and 16-slot baseplates

  • Compatible Expansion Baseplates: 5-slot and 10-slot baseplates

  • Slots Covered: Single slot

  • Module Installations: Unlimited

  • Scalable Systems: Supported

  • Backplane Current Draw: None

  • Status Indicators: None

  • Programming Requirement: None

  • Communication: None

  • I/O Count: None

  • Removal/Insertion Under Power: Supported

  • Vibration Prevention: Supported

  • Water Damage Prevention: Supported

  • Product Lifecycle: Active

Application Scenarios

  • Rack Protection: Prevents dust and debris from entering unused slots.

  • Cooling Efficiency: Maintains airflow in partially filled racks.

  • System Stability: Provides mechanical support for scalable configurations.

  • Operational Flexibility: Allows safe insertion and removal under power.

FAQ

Q: Does the IC694ACC310 require programming?  A: No, it is a passive filler module with no configuration needed.

Q: Can it be installed while the system is powered?  A: Yes, safe insertion and removal under power are supported.

Q: Is it compatible with both standard and expansion baseplates?  A: Yes, it supports 7, 12, and 16-slot standard baseplates as well as 5 and 10-slot expansion baseplates.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more