Skip to content

What are you looking for?


You may also like

GE Fanuc PACSystems RX3i IC694ACC310 Protective Blank Slot Filler ModuleGE Fanuc PACSystems RX3i IC694ACC310 Protective Blank Slot Filler ModuleGE Fanuc PACSystems RX3i IC694ACC310 Protective Blank Slot Filler Module
GE Fanuc PACSystems RX3i IC694ACC310 Protective Blank Slot Filler Module
GE Fanuc PACSystems RX3i IC694ACC310 Protective Blank Slot Filler Module
GE Fanuc PACSystems RX3i IC694ACC310 Protective Blank Slot Filler Module

GE Fanuc PACSystems RX3i IC694ACC310 Protective Blank Slot Filler Module


Only 10 left - Selling fast

PRODUCT SKU : IC694ACC310

PRODUCT TYPE : PLC Accessory

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Functional Purpose and Protective Benefits

The IC694ACC310 is a specialized hardware accessory designed to maintain the mechanical and environmental integrity of GE Fanuc PACSystems RX3i chassis. While often overlooked, the IC694ACC310 (Part Number: IC694ACC310) plays a critical role in system longevity by sealing unused backplane slots. This prevents the accumulation of conductive dust, metallic shavings, and moisture on sensitive backplane pins, which can lead to short circuits or signal degradation. Furthermore, installing these fillers ensures optimized airflow and vibration resistance within the rack assembly.

Comprehensive Technical Specifications

Detailed below are the physical and operational characteristics of the IC694ACC310 filler module:

  • Compatibility: All PACSystems RX3i Universal, Expansion, and Remote Backplanes.

  • Slot Footprint: Occupies a single (1) I/O slot.

  • Electrical Load: Zero (0) mA; draws no power from the 5V or 24V backplane bus.

  • Environmental Protection: Shields open connectors from moisture, dust, and airborne contaminants.

  • Mechanical Stability: Enhances rack rigidity and prevents module vibration in high-impact environments.

  • Installation: Supports "Hot Swapping" (Removal and insertion while the system is under power).

  • Configuration: No software programming or hardware configuration required.

  • Indicator Hardware: None (Passive module).

  • Mass: Approximately 0.11 kg (0.25 lbs).

System Integration and Maintenance

The IC694ACC310 is universally compatible across the RX3i range, including 7, 12, and 16-slot standard baseplates, as well as 5 and 10-slot expansion baseplates. It is considered best practice by GE Fanuc engineers to populate every empty slot in a mission-critical PLC rack with an IC694ACC310 to ensure the system meets industrial EMI/RFI shielding expectations and stays within thermal design parameters.

Common Technical Inquiries

Does the filler module impact the I/O count or addressing of the PLC?No. The IC694ACC310 is a passive plastic and metal housing with no internal circuitry. It does not communicate with the CPU and does not consume any I/O points or memory addresses.

Is there a limit to how many filler modules I can use in one rack?There is no limit. You can use as many IC694ACC310 units as needed to cover all unpopulated slots in your RX3i system.

Can this be used with older Series 90-30 backplanes?Yes, because the RX3i IC694 series shares the same physical form factor as the legacy Series 90-30 I/O, this filler can be used to protect older IC693 baseplates as well.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more