Skip to content

What are you looking for?


You may also like

GE Fanuc | IC693ALG221 Series 90-30 | 4-Channel Analog Input ModuleGE Fanuc | IC693ALG221 Series 90-30 | 4-Channel Analog Input ModuleGE Fanuc | IC693ALG221 Series 90-30 | 4-Channel Analog Input Module
GE Fanuc | IC693ALG221 Series 90-30 | 4-Channel Analog Input Module
GE Fanuc | IC693ALG221 Series 90-30 | 4-Channel Analog Input Module
GE Fanuc | IC693ALG221 Series 90-30 | 4-Channel Analog Input Module

GE Fanuc | IC693ALG221 Series 90-30 | 4-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : IC693ALG221

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC693ALG221 by GE Fanuc is a 4-channel analog current input module for Series 90-30 PLCs that accurately processes 4–20 mA and 0–20 mA signals, provides high-resolution measurements, electrical isolation between field and logic circuits, and fast update rates suitable for precise industrial control applications.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC693ALG221

  • Product Type: Analog Input Module

  • Series: Series 90-30

  • Weight: 0.69 lbs (0.31 kg)

  • Number of Input Channels: 4

  • Supported Input Ranges: 4–20 mA, 0–20 mA

  • Resolution:

    • 4–20 mA: 4 μA per step

    • 0–20 mA: 5 μA per step

  • Accuracy: ±0.1% full scale

  • Update Rate: 2 ms for all channels

  • Input Impedance: 250 Ω

  • Electrical Isolation: 1500 V RMS (field-to-logic)

  • Filter Response: 325 Hz

  • Default Input Range: 4–20 mA

  • Power Consumption:

    • 25 mA at 5 VDC

    • 100 mA at 24 VDC

  • Analog-to-Digital Conversion: Internal ADC scales 4–20 mA signals to 0–32000 (0 = 4 mA, 32000 = 20 mA)

  • Linearity: Less than 1 LSB

  • Common Mode Voltage: 200 V

  • Configuration: Hardware-configured input range via terminal block jumpers

  • Power Source: Isolated +24 VDC supplied by PLC

  • Mounting / Compatibility: Compatible with standard Series 90-30 I/O racks

Applications

  • High-precision analog signal acquisition for Series 90-30 PLC systems

  • Real-time monitoring and control of sensors with 4–20 mA or 0–20 mA outputs

  • Integration in modular PLC racks requiring fast update rates and electrical isolation

FAQ

Q: Can the module handle both 4–20 mA and 0–20 mA signals simultaneously?
A: The IC693ALG221 supports either 4–20 mA or 0–20 mA input per channel, configured via terminal block jumpers.

Q: What is the update rate for all channels?
A: All four channels are updated every 2 ms, providing rapid response for control loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more