Skip to content

What are you looking for?


You may also like

Emerson DeltaV KJ3243X1-BA1 Series 2 Profibus DP Interface CardEmerson DeltaV KJ3243X1-BA1 Series 2 Profibus DP Interface CardEmerson DeltaV KJ3243X1-BA1 Series 2 Profibus DP Interface Card
Emerson DeltaV KJ3243X1-BA1 Series 2 Profibus DP Interface Card
Emerson DeltaV KJ3243X1-BA1 Series 2 Profibus DP Interface Card
Emerson DeltaV KJ3243X1-BA1 Series 2 Profibus DP Interface Card

Emerson DeltaV KJ3243X1-BA1 Series 2 Profibus DP Interface Card


Only 10 left - Selling fast

PRODUCT SKU : KJ3243X1-BA1

PRODUCT TYPE : Profibus DP Communication Card

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Emerson DeltaV Profibus DP Card, model KJ3243X1-BA1, is a Series 2 communication interface designed to integrate Profibus DP devices into DeltaV Distributed Control Systems. Supporting both DP-V0 and DP-V1 protocols, this card enables high-speed communication with up to 31 devices per card. With galvanic isolation, hot-swappable functionality, and robust environmental ratings, it ensures safe and reliable operation in demanding industrial environments.

Technical Specifications

  • Manufacturer: Emerson

  • Series: DeltaV Control System

  • Model / Part Number: KJ3243X1-BA1

  • Category: PLCs / Machine Control

  • Subcategory: Profibus DP Communication Card

  • Supported Protocols: Profibus DP-V0 and DP-V1

  • Device Capacity: Up to 31 Profibus DP devices per card

  • Baud Rate: Up to 12 Mbps

  • Bus Connection: 2-wire or 4-wire Profibus DP

  • Hot-Swappable: Yes, for simplified maintenance

  • Isolation: Galvanic isolation between Profibus DP bus and DeltaV controller

  • Power Requirements: 24 VDC nominal (21.6–26.4 VDC range)

  • Power Consumption: 1.5 W maximum

  • Operating Temperature: -40°C to +70°C (-40°F to +158°F)

  • Storage Temperature: -40°C to +85°C (-40°F to +185°F)

  • Humidity: 5%–95% non-condensing

  • Vibration Resistance: 0.03 g rms per axis, 5–500 Hz

  • Shock Resistance: 15 g, 11 ms half-sine pulse

Application Scenarios

  • Integrates Profibus DP field devices into DeltaV distributed control systems.

  • Suitable for industries such as power generation, oil & gas, and chemical processing.

  • Provides reliable communication in environments with high vibration and temperature extremes.

FAQ

Q: How many Profibus devices can be connected to this card?  A: The KJ3243X1-BA1 supports up to 31 Profibus DP devices per card.

Q: What protocols are supported?  A: It supports both Profibus DP-V0 and DP-V1 communication protocols.

Q: Is the card hot-swappable?  A: Yes, it can be replaced without shutting down the system, simplifying maintenance.

Q: How does this compare to earlier Profibus cards?  A: The Series 2 KJ3243X1-BA1 offers higher baud rates, improved isolation, and enhanced environmental resilience compared to earlier versions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more