Product Description

The Emerson DeltaV RTD Input Module, model KJ3002X1-BF1 (order code 12P1732X042), is designed for precise temperature measurement in process automation systems. This module interfaces directly with RTD sensors, thermocouples, millivolt, and VDC inputs, converting analog temperature signals into digital data for DeltaV controllers. With high accuracy, fast update rates, and robust environmental ratings, it ensures reliable performance in demanding industrial environments.

Technical Specifications

  • Manufacturer: Emerson

  • Series: DeltaV Control System

  • Model / Part Number: KJ3002X1-BF1 (12P1732X042)

  • Category: PLCs / Machine Control

  • Subcategory: RTD Input Module

  • Channels: 8 input channels

  • Supported Input Types: RTD, thermocouple, millivolt, VDC

  • Accuracy: ±0.1%

  • Update Rate: 8 inputs processed within 100 ms

  • Shielding: Included for noise reduction

  • Power Requirements:

    • Voltage: 12 VDC

    • Current: 160 mA

    • Power Consumption: 1.5 W

  • Environmental Ratings:

    • Operating Temperature: -40°C to +85°C

    • Shock & Vibration: Meets ISA-S71.04-1985 standards

    • Airborne Contaminants Class: G3

    • Humidity: 5%–95% non-condensing

    • Protection Class: IP20

  • Physical Specifications:

    • Module Width: 8-wide assembly

Application Scenarios

  • Interfaces with RTD sensors for accurate temperature monitoring.

  • Suitable for industries such as power generation, petrochemical, and water treatment.

  • Provides fast and reliable signal conversion for critical process control.

FAQ

Q: What types of inputs are supported?  A: The KJ3002X1-BF1 supports RTD, thermocouple, millivolt, and VDC signals.

Q: How many channels are available?  A: It provides eight independent input channels.

Q: What is the accuracy of this module?  A: It delivers ±0.1% accuracy across supported input types.

Q: How does this compare to thermocouple-only modules?  A: Unlike thermocouple-specific modules, the KJ3002X1-BF1 supports multiple input types, making it more versatile for temperature measurement applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more