Skip to content

What are you looking for?


You may also like

ControlLogix DC Output Module | 1756-OB16I | Allen-BradleyControlLogix DC Output Module | 1756-OB16I | Allen-BradleyControlLogix DC Output Module | 1756-OB16I | Allen-Bradley
ControlLogix DC Output Module | 1756-OB16I | Allen-Bradley
ControlLogix DC Output Module | 1756-OB16I | Allen-Bradley
ControlLogix DC Output Module | 1756-OB16I | Allen-Bradley

ControlLogix DC Output Module | 1756-OB16I | Allen-Bradley


Only 10 left - Selling fast

PRODUCT SKU : 1756-OB16I

PRODUCT TYPE : DC Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1756-OB16I is a 16-point DC output module designed for Allen-Bradley ControlLogix systems. Each output is individually isolated, ensuring reliable operation and protection across control circuits. This module delivers precise switching performance for industrial DC loads, featuring fast response times, configurable electronic keying, and full compatibility with ControlLogix backplanes.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model / Part Number: 1756-OB16I

  • Module Type: DC Output Module, ControlLogix Series

  • Outputs: 16 individually isolated channels

  • Pilot Duty: 2 A (DC-13 SQ)

  • Voltage Category: 12/24V DC sink/source

  • Operating Voltage Range: 10–30V DC

  • Output Switching Times:

    • Off-to-On: 1 ms max

    • On-to-Off: 2 ms max

  • Current Draw: 350 mA @ 5.1V, 2.5 mA @ 24V

  • Backplane Power Consumption: 1.8 W

  • Maximum Power Dissipation: 3.6 W @ 60°C, Thermal Dissipation 12.28 BTU/hr

  • Off-State Leakage: Max 0.5 mA per point

  • On-State Voltage Drop: Max 1.2 V @ 2 A

  • Current per Point: 2 A @ 30°C; 1 A @ 60°C (linear derating)

  • Current per Module: 8 A @ 30°C; 4 A @ 60°C (linear derating)

  • Surge Current per Point: 4 A for 10 ms, repeatable every 2 s

  • Minimum Load Current: 1 mA per point

  • Scheduled Outputs: Synchronization within 16.7 s max (reference to Coordinated System Time)

  • Output States in Fault/Program Mode: Hold last state, configurable On/Off

  • Isolation Voltage:

    • Outputs-to-Backplane: 250 V continuous, basic insulation

    • Output-to-Output: 125 V continuous, basic insulation

    • Tested at 1350 V AC for 2 s

  • Module Keying: Electronic, software configurable

  • Fusing: Not included; fused IFM recommended

  • Removable Terminal Block Compatibility: 1756-TBCH, 1756-TBS6H

  • RTB Keying: User-defined mechanical

  • Slot Width: 1

  • Wire Category: 1

  • Temperature Codes: North American T4A, IEC T4

  • Enclosure: Open-style, no housing

Application Notes

  • Suitable for DC load control, pilot duty applications, and automated machine systems

  • Compatible with ControlLogix backplane for seamless integration

  • Ideal for high-reliability industrial switching with isolated outputs

FAQ

Q: How many outputs does the 1756-OB16I provide?
A: 16 individually isolated DC output points.

Q: What is the maximum current per channel?
A: 2 A at 30°C, derated to 1 A at 60°C.

Q: Is the module isolated from the backplane and between outputs?
A: Yes, outputs-to-backplane and output-to-output isolation is provided.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more