Product Description

The Allen Bradley MVI56E-MNET is an enhanced Modbus TCP/IP client/server interface module designed for ControlLogix systems. It enables seamless communication between ControlLogix processors and Modbus TCP/IP devices, supporting high-speed Ethernet connectivity and flexible data mapping. With Add-On-Instruction (AOI) configuration and sample ladder logic support, the module simplifies integration while providing robust performance in industrial automation networks.

Technical Specifications

  • Manufacturer Allen Bradley (ProSoft Technology)

  • Product Line ControlLogix

  • Product Type Modbus TCP/IP Interface Module

  • Part Number MVI56E-MNET

  • Weight 3.00 lbs (1.36 kg)

  • Backplane Current Load 800 mA @ 5 V DC, 3 mA @ 24 V DC

  • Module Width Single slot

  • Compatible Rack ControlLogix chassis (local or remote)

  • Compatible Processor ControlLogix processor version 10 or higher

  • Data Size 5000 words, 16-bit registers

  • Configuration Options Add-On-Instruction (AOI), sample ladder logic

  • Communication Port 1 × RJ45 Ethernet interface

  • Data Rate 10/100 Mbps

  • Ethernet Port 10/100 Base-T

  • User-Definable Memory Mapping 5000 registers

  • LED Indicators Battery Status (ERR), Application Status (APP), Module Status (OK)

  • Operating Temperature 0–60 °C (32–140 °F)

  • Storage Temperature –40–85 °C (–40–185 °F)

  • Operating Shock 30 g

  • Relative Humidity 5–95% non-condensing

  • Protection Conformal-coated

Application Scenarios

  • Integration of ControlLogix systems with Modbus TCP/IP devices

  • Distributed automation requiring client/server communication over Ethernet/IP

  • Industrial networks needing flexible data mapping and high-speed communication

FAQ

Q: What processors are compatible with the MVI56E-MNET?  A: ControlLogix processors version 10 or higher.

Q: How many registers can be mapped?  A: Up to 5000 user-definable registers.

Q: What communication speed does the module support?  A: 10/100 Mbps Ethernet connectivity.

Comparable Models

  • MVI56E-MNET: Enhanced Modbus TCP/IP client/server module (this model)

  • MVI56-MCM: Modbus serial communication module

  • MVI56E-MCM: Enhanced Modbus serial communication module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more