Skip to content

What are you looking for?


You may also like

1734-IE8C | Allen-Bradley POINT I/O 8-Channel High-Density Analog Current Input Module1734-IE8C | Allen-Bradley POINT I/O 8-Channel High-Density Analog Current Input Module1734-IE8C | Allen-Bradley POINT I/O 8-Channel High-Density Analog Current Input Module
1734-IE8C | Allen-Bradley POINT I/O 8-Channel High-Density Analog Current Input Module
1734-IE8C | Allen-Bradley POINT I/O 8-Channel High-Density Analog Current Input Module
1734-IE8C | Allen-Bradley POINT I/O 8-Channel High-Density Analog Current Input Module

1734-IE8C | Allen-Bradley POINT I/O 8-Channel High-Density Analog Current Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1734-IE8C

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1734-IE8C is a high-density analog input module designed for the Allen-Bradley POINT I/O system, providing eight single-ended channels for precise current sensing. This module is an ideal solution for industrial applications requiring a compact footprint without sacrificing channel density. It efficiently converts analog signals from field devices—such as pressure transmitters, flow meters, and temperature sensors—into digital data for processing by Logix-based controllers. The 1734-IE8C supports both 0–20 mA and 4–20 mA input ranges, allowing for versatile integration across various process control environments.

Technical Specifications

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Series: POINT I/O

  • Model Number: 1734-IE8C

  • Input Quantity: 8 Channels (Single-ended, Non-isolated)

  • Input Signal Range: 0 to 20 mA or 4 to 20 mA

  • Resolution: 16-bit (0 to 21 mA corresponds to 0–32767 counts)

  • POINTBus Current: 75 mA maximum @ 5V DC

  • Power Dissipation: 0.6 Watts @ 28.8V DC maximum

  • Thermal Dissipation: 2.0 BTU/hr @ 28.8V DC maximum

  • Isolation Voltage: 50V (Continuous), tested at 1500V AC for 60 seconds (Field-to-System)

  • Input Impedance: 50 Ohms

  • Keyswitch Position: 3

  • Terminal Base Requirement: Compatible with 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS

  • Environmental Rating: Open-style enclosure

  • Physical Dimensions: 75.5mm x 12mm x 56mm

  • Unit Weight: 0.04 kg (0.088 lbs)

Installation and System Integration

The 1734-IE8C module snaps easily into the POINT I/O terminal base, utilizing a sliding mechanism for secure attachment to adjacent modules. The high-density 8-channel design significantly reduces the required DIN rail space compared to standard 2 or 4-channel modules. It is essential to ensure that the terminal base is correctly wired, as there is no isolation between individual input channels. For applications in high-vibration environments, the 1734-TBS (spring clamp) base is recommended to maintain electrical contact integrity.

Frequently Asked Questions

Does the 1734-IE8C support HART protocol pass-through?No, the 1734-IE8C is a standard analog current input module. If HART communication is required for instrument diagnostics, the 1734-IE8CH (HART-enabled version) should be used instead.

Can I mix 0–20mA and 4–20mA sensors on the same module?Yes, the input range is software-configurable via Studio 5000 or RSLogix 5000. You can define the specific current range for each channel according to the connected field device requirements.

What is the significance of the Keyswitch Position 3?The keyswitch on the terminal base must be set to position 3 before inserting the 1734-IE8C. This mechanical interlock prevents the accidental insertion of a different module type into a base wired for high-density current inputs, protecting the hardware from electrical damage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more