PRODUCT SKU : 1762-L40BWAR

PRODUCT TYPE : Programmable Logic Controller

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

System Capabilities

The 1762-L40BWAR is a versatile and compact programmable logic controller (PLC) from the MicroLogix 1200 family, designed to handle moderate to complex automation tasks. This 40-point unit provides a high-density I/O count, featuring a mix of 24V DC discrete inputs and robust relay outputs. It is powered by a wide-range AC input, making it suitable for global industrial applications where varying voltage standards are present. The controller is engineered for field-expandability, allowing users to add 1762 expansion I/O modules to meet growing system requirements.

Technical Characteristics

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Series: MicroLogix 1200

  • Model Number: 1762-L40BWAR

  • Total I/O Count: 40 Points

  • Input Specifications: 24 DC Inputs (20 standard and 4 high-speed ports)

  • Output Specifications: 16 Relay Outputs (form A and form C)

  • Operating Voltage: 120V to 240V AC (Operating range 85–264V AC)

  • Input Circuit Type: Sink/Source (User-configurable)

  • Relay Contact Rating: 24–125V DC; 120–240V AC

  • Communication Interface: 8-pin mini-DIN RS-232 port

  • Supported Protocols: DF1, DH-485, Modbus RTU Slave, and ASCII

  • Inrush Current: 25A for 8ms (120V AC); 40A for 4ms (240V AC)

  • Thermal Dissipation: 22 Watts

  • Memory Type: 6KB non-volatile (User program and data)

  • Mechanical Weight: 1.67 kg (3.69 lbs)

Operational Features and Programming

The 1762-L40BWAR is optimized for applications requiring reliable relay switching and high-speed counting. The four integrated high-speed inputs allow for interfacing with encoders or flow meters at rates up to 20 kHz. System configuration is typically performed using RSLogix 500 software, providing a stable ladder-logic environment for industrial sequencing and machine control. Its relay outputs are rated for over 20 million mechanical cycles, ensuring longevity in high-cycle packaging, material handling, and HVAC control systems.

Frequently Asked Questions

Does the 1762-L40BWAR support memory expansion?While the internal memory is fixed at 6KB, the unit supports the use of a 1762-MM1 memory module for program backup and transport between controllers.

Can I communicate with a modern PC without a serial port?To program the 1762-L40BWAR using a modern computer, a 1747-UIC (USB to DH-485) or a high-quality USB-to-RS232 converter (such as the 9300-USBS) is required to interface with the mini-DIN port.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more