Skip to content

What are you looking for?


You may also like

Allen-Bradley Linking Device Module 1788-EN2DN for EtherNet/IPAllen-Bradley Linking Device Module 1788-EN2DN for EtherNet/IPAllen-Bradley Linking Device Module 1788-EN2DN for EtherNet/IP
Allen-Bradley Linking Device Module 1788-EN2DN for EtherNet/IP
Allen-Bradley Linking Device Module 1788-EN2DN for EtherNet/IP
Allen-Bradley Linking Device Module 1788-EN2DN for EtherNet/IP

Allen-Bradley Linking Device Module 1788-EN2DN for EtherNet/IP


Only 10 left - Selling fast

PRODUCT SKU : 1788-EN2DN

PRODUCT TYPE : Linking Device Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1788-EN2DN is a robust Linking Device Module from Allen-Bradley designed to bridge DeviceNet and EtherNet/IP networks. It provides secure, reliable communication and flexible power options, suitable for industrial automation environments where seamless network integration is critical.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Part Number: 1788-EN2DN

  • Product Type: Linking Device Module

  • Power Requirements:

    • Input: 24V DC, 150 mA (Class 2 / SELV)

    • DeviceNet: 24V DC, 60 mA (Class 2 / SELV)

    • Logic Supply: 24V DC SELV/PELV, ±15–20%, 100 mA max

    • DeviceNet Supply: 24V DC SELV/PELV, 20 mA max

  • Wiring Category:

    • Power Ports: 2

    • Communication Ports: 2

  • Isolation Voltage: 30V continuous, basic insulation (power/system, Ethernet/system, DeviceNet/system, USB/system)

  • Type Tested: 500V AC for 60 s

  • EtherNet/IP Connection: RJ45 Connector

  • Dimensions: 5.1 × 12.7 × 27.9 cm

  • Weight: 1.4 kg

Features

  • Provides reliable network bridging between DeviceNet and EtherNet/IP.

  • Supports SELV/PELV power isolation for safety and stability.

  • Compact form factor suitable for control panels and industrial racks.

  • High-quality insulation and tested for overvoltage conditions.

Applications

  • DeviceNet to EtherNet/IP integration in industrial networks.

  • Factory automation requiring secure and stable communications.

  • Linking PLC systems with multiple network protocols.

FAQ

Q: What voltage does the 1788-EN2DN require?
A: Logic and DeviceNet supply require 24V DC with SELV/PELV compliance.

Q: How many network ports are included?
A: 2 power ports and 2 communication ports, including RJ45 for EtherNet/IP.

Q: Can it be installed in high-humidity environments?
A: Yes, suitable for industrial conditions with proper installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more