Overview

The Allen-Bradley 1794-IE12 is a 12-point analog input module from the FLEX I/O series designed for scalable distributed control applications. It provides high-resolution signal acquisition for both voltage and current inputs, offering accuracy and reliability for analog process measurements in industrial automation environments.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: FLEX I/O

  • Model / Part Number: 1794-IE12

  • Product Type: Analog Input Module

  • Number of Inputs: 12 single-ended, non-isolated channels

  • Resolution:

    • Voltage: 320 µV per count

    • Current: 0.641 µA per count

  • Conversion Method: Successive approximation

  • Input Current Range: 4–20 mA

  • Calibration: Factory-calibrated (no user adjustment required)

  • Status Indicators: One dual-color (green/red) LED for power and module status

  • Isolation: Non-isolated single-ended channels

  • Dimensions (L x W x H): 5.33 cm × 9.4 cm × 9.4 cm

  • Shipping Weight: 2 kg

Key Features

  • 12-channel analog input for scalable FLEX I/O applications

  • Supports both current and voltage signal processing

  • Successive approximation ensures fast and accurate conversions

  • Factory-calibrated for plug-and-play reliability

  • Compact and modular design simplifies installation and system expansion

Application Scenarios

  • Process control and monitoring in manufacturing plants

  • Integration with PLC systems for analog signal acquisition

  • Measurement of temperature, pressure, and flow in distributed I/O systems

  • Ideal for applications requiring high-density analog input capability

FAQs

Q: How many channels does the 1794-IE12 support?
A: It offers 12 single-ended, non-isolated analog input channels.

Q: What signal ranges does it accept?
A: The module accepts both voltage and current signals, including standard 4–20 mA current inputs.

Q: Is calibration required?
A: No user calibration is necessary; the unit is factory-calibrated for long-term accuracy.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more