Skip to content

What are you looking for?


You may also like

Allen-Bradley 2711PC-T10C4D8 PanelView Plus 6 600 Compact Touch TerminalAllen-Bradley 2711PC-T10C4D8 PanelView Plus 6 600 Compact Touch TerminalAllen-Bradley 2711PC-T10C4D8 PanelView Plus 6 600 Compact Touch Terminal
Allen-Bradley 2711PC-T10C4D8 PanelView Plus 6 600 Compact Touch Terminal
Allen-Bradley 2711PC-T10C4D8 PanelView Plus 6 600 Compact Touch Terminal
Allen-Bradley 2711PC-T10C4D8 PanelView Plus 6 600 Compact Touch Terminal

Allen-Bradley 2711PC-T10C4D8 PanelView Plus 6 600 Compact Touch Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711PC-T10C4D8

PRODUCT TYPE : PanelView

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 2711PC-T10C4D8 is a 10.4-inch compact operator terminal in the PanelView Plus 6 600 series, providing high-resolution color display with touchscreen control. Designed for operator interface applications, it supports Ethernet, RS-232, and USB communication, making integration with PLC systems seamless. Its robust construction allows use in NEMA/UL Type 12, 13, 4X, and IEC IP54/IP65 environments (indoor use).

Key Features

  • Display Size: 10.4-inch color active-matrix TFT, 640 x 480 resolution, 18-bit graphics

  • Touch Input: Analog resistive touchscreen

  • Memory: 512 MB nonvolatile memory and 512 MB RAM

  • Communication Ports: Ethernet, RS-232, 2 USB host ports

  • Backlight: CCFL, 50,000-hour minimum, field replaceable

  • Display Area: 211 x 158 mm (8.3 x 6.2 in.)

  • Input Voltage: 18–32V DC (24V nominal)

  • Input Power: 24V DC

  • Enclosure: NEMA/UL Type 12, 13, 4X; IEC IP54, IP65 (indoor use)

  • Lifecycle Status: End of life

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PanelView Plus 6 Compact

  • Part Number: 2711PC-T10C4D8

  • Operator Input: Touchscreen

  • Display Type: Color active-matrix TFT

  • Resolution: 640 x 480, 18-bit

  • Internal Memory: 512 MB Flash / 512 MB RAM

  • Integrated Ports: Ethernet, RS-232, 2 USB host

  • Backlight: CCFL, 50,000-hour minimum

  • Weight: 4.50 lbs (2.04 kg)

Application Scenarios

The 2711PC-T10C4D8 is ideal for:

  • Machine Monitoring: Compact panels requiring operator interface

  • Process Visualization: High-resolution color display of complex data

  • Network Integration: Ethernet, RS-232, or USB connectivity

  • Protected Environments: NEMA/UL Type 12, 13, 4X, IEC IP54/IP65

FAQs

  • Q: Display Size and Type: 10.4-inch color TFT with analog resistive touchscreen

  • Q: Communication Options: Ethernet, RS-232, 2 USB host ports

  • Q: Memory Capacity: 512 MB nonvolatile memory and 512 MB RAM

  • Q: Backlight Replaceable: Yes, CCFL backlight is field replaceable

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more