Skip to content

What are you looking for?


You may also like

Allen Bradley 20-COMM-E PowerFlex 7-Class EtherNet/IP AdapterAllen Bradley 20-COMM-E PowerFlex 7-Class EtherNet/IP AdapterAllen Bradley 20-COMM-E PowerFlex 7-Class EtherNet/IP Adapter
Allen Bradley 20-COMM-E PowerFlex 7-Class EtherNet/IP Adapter
Allen Bradley 20-COMM-E PowerFlex 7-Class EtherNet/IP Adapter
Allen Bradley 20-COMM-E PowerFlex 7-Class EtherNet/IP Adapter

Allen Bradley 20-COMM-E PowerFlex 7-Class EtherNet/IP Adapter


Only 10 left - Selling fast

PRODUCT SKU : 20-COMM-E

PRODUCT TYPE : Drive Communication Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 20-COMM-E acts as the high-speed communication gateway for PowerFlex 7-Class AC drives. This adapter enables seamless integration of motor control assets into an EtherNet/IP network, allowing for real-time control, configuration, and data collection. By utilizing the internal DPI (Drive Peripheral Interface) protocol, it provides the bridge between field-level drive parameters and enterprise-level Ethernet architectures. We supply this module as 100% Brand New and Original, ensuring peak network stability and zero-hour operational life.

Technical Specifications

The 20-COMM-E optimizes data throughput for complex drive lineups via the following technical parameters:

Feature Specification
Manufacturer Allen Bradley
Compatible Drives PowerFlex 70, 700, 700H, 700S, 753, 755
Network Protocol EtherNet/IP
Data Rates 10/100 Mbps (Half or Full Duplex)
Drive Protocol DPI (125 kbps or 500 kbps)
TCP Connections Up to 30 Simultaneous Connections
Packet Rate 400 I/O packets/sec (200 In / 200 Out)
Device Type Multi-Cast Support
Operating Temp -10 to 50 °C (14 to 122 °F)
Weight 0.44 lbs (0.20 kg)

Engineering Advantages

The 20-COMM-E provides critical hardware and software advantages for industrial network engineers:

  • High-Density Packet Processing: The adapter handles up to 400 I/O packets per second. This capacity ensures that high-speed motion control or rapid interlocking signals reach the drive without the latency spikes associated with low-tier communication cards.

  • Versatile Topology Support: The module supports both 10 Mbps and 100 Mbps data rates in half or full duplex. This auto-negotiation capability allows it to function within legacy network hubs or modern high-speed managed switches without manual configuration.

  • Multi-Master Control: Supporting up to 30 simultaneous TCP connections, the 20-COMM-E allows multiple controllers or HMI units to access drive data concurrently. This enables a supervisor PC to collect energy analytics while a PLC maintains primary control of the motor.

  • Internal DPI Integration: The module mounts directly into the drive’s internal communication bay. This internal installation protects the adapter from external electromagnetic interference (EMI) and physical damage, unlike external protocol converters.

FAQs

  • Can I install the 20-COMM-E while the drive is powered?

    No. You must remove all power from the PowerFlex drive before installing or removing the 20-COMM-E adapter. Failure to do so can result in permanent damage to the DPI port on the drive control board or the adapter itself.

  • Does this adapter support the PowerFlex 4-Class (e.g., PowerFlex 40)?

    No. The 20-COMM-E specifically targets 7-Class drives using the DPI protocol. For PowerFlex 4-Class drives, which utilize the DSI protocol, you require the 22-COMM-E adapter.

  • How do I assign an IP address to a brand new 20-COMM-E?

    A new unit defaults to DHCP/BOOTP enabled. You can assign the IP address using the Rockwell BootP/DHCP Utility or via the DriveExplorer/Connected Components Workbench (CCW) software using a 1203-USB converter if the network is not yet active.

  • What is the significance of the 500 kbps DPI data rate?

    The 500 kbps rate maximizes the internal communication speed between the adapter and the drive's main control board. This ensures that the high-speed Ethernet data is not bottlenecked by the internal drive interface, maintaining synchronized control loops.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more
Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Selecting the correct control platform represents a foundational engineering decision in factory automation. System designers must carefully balance technical parameters against long-term operational requirements when implementing a Programmable Logic Controller (PLC). This article examines the critical evaluation metrics, physical scale classifications, and operational architectures of modern control systems.

Read more