Skip to content

What are you looking for?


You may also like

Allen-Bradley 1771-IXE 8-Channel Thermocouple Input ModuleAllen-Bradley 1771-IXE 8-Channel Thermocouple Input ModuleAllen-Bradley 1771-IXE 8-Channel Thermocouple Input Module
Allen-Bradley 1771-IXE 8-Channel Thermocouple Input Module
Allen-Bradley 1771-IXE 8-Channel Thermocouple Input Module
Allen-Bradley 1771-IXE 8-Channel Thermocouple Input Module

Allen-Bradley 1771-IXE 8-Channel Thermocouple Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1771-IXE

PRODUCT TYPE : Thermocouple / Millivolt Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 1771-IXE module by Allen-Bradley provides precise thermocouple and millivolt signal acquisition for PLC-5 systems. It supports 8 input channels, configurable for the same type or two different types, and delivers high-resolution 15-bit measurement with fast 50 ms update per 8 channels. Ideal for temperature monitoring and low-voltage sensor applications in industrial automation.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model Number: 1771-IXE

  • Product Type: Thermocouple / Millivolt Input Module

  • Series: PLC-5

  • Number of Inputs: 8 (configurable as 8 same-type or 4 + 4 of different types)

  • Thermocouple Types Supported: E, J, K, T, R, S

  • Voltage Range: ±99.99 mV (Thermocouple Types); ±100 mV (Resistance Inputs)

  • Cold Junction Compensation: 0–60°C

  • Backplane Current: 750 mA

  • Data Format: 4-Digit BCD, 2's Complement, Signed Magnitude

  • Resolution: 1°C / 1°F

  • Processor Compatibility: Any A-B processor using 1771 I/O with Block Transfer

  • Model Status: Earlier Model

  • Calibration: Auto-Calibration (offset & gain)

  • Typical DC Signal Delay (Off): 50 ms

  • Typical AC Signal Delay (Off): 45 ±15 ms

  • Mounting Type: Rack-Mountable

  • Chassis Compatibility: Any 1771 I/O Chassis

  • Number of I/O: 8 Floating Differential

  • Weight: 1.0 lbs (0.45 kg)

Key Features

  • High-precision thermocouple and mV signal input

  • Auto-calibration for offset and gain

  • Fast 50 ms per 8-channel update rate

  • Compatible with all PLC-5 processors and standard 1771 I/O chassis

Applications

  • Temperature monitoring and control in industrial systems

  • Low-voltage signal acquisition from thermocouples or millivolt sensors

  • Integration with PLC-5 I/O networks for process automation

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more