PRODUCT SKU : 51305489-800

PRODUCT TYPE : Shielded Power Cables

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51305489-800, also cataloged as the 51305489-800 Shielded Power Cables, operates as a dedicated hardware component for power distribution and inter-module signal transmission within Honeywell TDC 3000, TPS, and Experion PKS networks.

Hardware Specifications

Parameter Specification
Model 51305489-800
Brand Honeywell
Origin USA / Global Manufacturing
Weight 0.1 kg
Operating Temp -20 to +85 deg C
Power Consumption Passive wiring component
Component Type Shielded industrial power/communication cable
Voltage Rating 240 VAC (Rev D)
Connector Type Multi-pin industrial connector
Cable Jacket Abrasion, chemical, and oil-resistant rugged PVC/Polymer
System Compatibility Honeywell TPS, TDC 3000, Experion PKS

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The 51305489-800 cable assembly feeds line power to control nodes while carrying digital communication links between controllers and expansion chassis. When routed alongside low-level instrumentation lines configured for 4-20 mA HART loop protocol transmission, the continuous outer shield layer prevents switching transients and power frequency noise from coupling onto signal conductors.

By suppressing electromagnetic and radio-frequency interference (EMI/RFI), the shielded construction maintains channel-to-channel isolation parameters and preserves transmitter signal integrity across adjacent process input cards.

Frequently Asked Questions

Q: What is the rated voltage capacity for the 51305489-800 cable hardware?

A: The cable assembly is specified for operation at up to 240 VAC (Revision D rating).

Q: How does the cable jacket protect internal conductors against chemical degradation?

A: The outer jacket uses a rugged PVC/polymer formulation designed to resist oil contamination, chemical exposure, and mechanical abrasion.

Q: Can the multi-pin industrial connectors be mated without special wiring tools?

A: Yes, the cable comes equipped with factory-terminated multi-pin industrial connectors designed for direct keyed interface with compatible Honeywell modules.

Field Installation Guidelines

  • Verify that primary system circuit breakers are opened and de-energized prior to mating or unmating the multi-pin connectors.
  • Align connector keying features carefully before engaging the plug into the chassis receptacle to prevent pin deflection.
  • Secure multi-pin retaining latches or screws fully to ensure a low-resistance earth contact through the connector shield housing.
  • Maintain recommended conduit bend radii during wireway routing to protect the shield braid and internal conductors from mechanical strain.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more