Product Details
The Bently Nevada 22810-00-13-10-02, also cataloged as the 22810 Vibration Sensor Proximity Probe, operates as a dedicated hardware component for contactless dynamic vibration and displacement measurement within 3300/3500 Machinery Protection Systems.
Suffix Breakdown & Model Matrix
| Option Field | Code | Configuration Detail |
|---|---|---|
| Unthreaded Length | 00 | 0.0 in unthreaded body length |
| Overall Case Length | 13 | 1.3 in overall case length |
| Total Length & Mounting | 10 | 10.0 meters total length |
| Agency Approval | 02 | CSA / NRTL / C agency approvals |
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 22810-00-13-10-02 |
| Brand | Bently Nevada |
| Origin | USA |
| Weight | 0.45 kg |
| Dimensions | 8 mm probe tip diameter, 1.3 in case length |
| Operating Temp | -35 deg C to +177 deg C (-31 deg F to +350 deg F) |
| Power Consumption | Passive sensor; driven via Proximitor transducer excitation |
| Sensing Range | 2 mm to 13 mm |
| Linear Range | 0 mm to 10 mm |
| Sensitivity | 7.87 mV/um |
| Cable Length | 10 meters |
| Connector Type | 2-pin MIL-C-5015 |
| Output Signal | Proportional AC/DC voltage output |
| Frequency Response | 10 kHz to 1 MHz |
| Input Impedance | 50 ohm |
| Accuracy | +/-0.5% |
| Resolution | 100 mV |
Eddy-Current Probe Scaling and Gap Voltage Validation
The 22810-00-13-10-02 proximity probe utilizes eddy-current sensing principles to convert physical shaft displacement into a high-frequency proportional voltage signal. Achieving proper eddy-current probe scaling requires maintaining a verified physical installation distance corresponding to -10 VDC gap voltage validation targets at nominal shaft centerlines. Signal integrity across the 10-meter cable assembly prevents cross-talk suppression degradation, ensuring reliable input signal conditioning for downstream spectral FFT analysis and real-time rotor dynamics monitoring.
Frequently Asked Questions
Q: What is the target gap setting procedure for establishing the nominal operating center of the probe?
A: Mechanical insertion must be adjusted while monitoring the Proximitor output voltage until the nominal -10 VDC gap voltage reference target is achieved.
Q: Can the 10-meter cable be trimmed or spliced in the field?
A: No, trimming or splicing alters total circuit resistance and capacitance, which ruins the 7.87 mV/um sensitivity scaling calibration.
Field Installation Guidelines
- Mount the probe body into the bearing housing or rigid mounting bracket, ensuring at least 30 mm of clearance from adjacent conductive metals to prevent side-view false target loading.
- Thread the probe carefully into the bracket engagement until the probe tip reaches the target surface without physical contact.
- Connect the 2-pin MIL-C-5015 connector securely and apply self-fusing silicone tape over the connection for moisture sealing.
- Route the 10-meter cable through grounded rigid or flexible metallic conduit away from high-voltage motor supply lines to reduce electro-magnetic interference.
- Ground the cable shield at the Proximitor enclosure end only, keeping the probe tip isolated from machine frame ground loops.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.