Only 10 left - Selling fast

PRODUCT SKU : 200350-02-00-CN

PRODUCT TYPE : Accelerometers

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 200350-02-00-CN, also cataloged as the 200350 Accelerometer, operates as a dedicated hardware component for piezoelectric seismic vibration detection and dynamic casing acceleration measurement within Bently Nevada Machinery Monitoring Systems.

Suffix Breakdown & Model Matrix

Option Field Code Configuration Detail
Mounting Stud Option 02 1/4-28 to M8 x 1.25 Beryllium Copper (BeCu) stud
Sensitivity Tolerance Option 00 100 mV/g +/- 20% sensitivity tolerance
Agency Approval Option CN China Hazardous Area Approvals

Hardware Specifications

Parameter Specification
Model 200350-02-00-CN
Brand Bently Nevada
Origin USA
Weight 0.10 kg
Dimensions Standard hex-body piezoelectric accelerometer profile
Operating Temp -54 deg C to +121 deg C
Power Consumption Powered via constant-current loop supply (2 to 10 mA)
Nominal Sensitivity 100 mV/g (10.2 mV/m/s^2)
Mounting Stud 1/4-28 UNF to M8 x 1.25 BeCu
Enclosure Sealing Hermetically sealed stainless steel housing

Rotor Dynamics and Dynamic Signal Conditioning

The 200350-02-00-CN sensor captures high-frequency casing vibration signals associated with rolling element bearing degradation and gear mesh frequencies. Internal piezoelectric sensing elements generate a charge output proportional to acceleration, which is converted to a low-impedance voltage signal. Proper stud torquing prevents mounting resonance shifts, maintaining frequency response across the rotor dynamics spectrum. Shielded twisted-pair wiring suppresses cross-talk degradation and high-frequency noise interference along field cable paths to the monitoring rack.

Frequently Asked Questions

Q: What mounting stud thread pitch is supplied with the option 02 configuration?

A: Option 02 provides a dual-threaded beryllium copper stud with a 1/4-28 UNF thread on the sensor side and an M8 x 1.25 thread on the machine surface side.

Q: Does the 200350-02-00-CN require an external charge amplifier?

A: No, the sensor contains internal signal conditioning electronics requiring only a standard constant-current power source (2 to 10 mA) over two-wire loop connections.

Field Installation Guidelines

  1. Prepare the mounting surface by spot-facing a flat, smooth area free of paint, rust, and burrs around the tapped hole.
  2. Apply a thin layer of silicone grease to the mounting interface to ensure acoustic coupling between the sensor base and machine casing.
  3. Thread the M8 x 1.25 end of the beryllium copper stud into the machine housing and torque the sensor onto the 1/4-28 stud end according to standard torque limits.
  4. Route the twisted, shielded two-conductor cable through grounded conduit, avoiding parallel runs next to high-voltage power lines.
  5. Terminate the cable shield at the monitoring system chassis ground terminal only, leaving the sensor-end shield ungrounded to prevent ground loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more