Skip to content

What are you looking for?


You may also like

1794-TB32 FLEX I/O Module | Allen-Bradley | 32 Digital Inputs1794-TB32 FLEX I/O Module | Allen-Bradley | 32 Digital Inputs1794-TB32 FLEX I/O Module | Allen-Bradley | 32 Digital Inputs
1794-TB32 FLEX I/O Module | Allen-Bradley | 32 Digital Inputs
1794-TB32 FLEX I/O Module | Allen-Bradley | 32 Digital Inputs
1794-TB32 FLEX I/O Module | Allen-Bradley | 32 Digital Inputs

1794-TB32 FLEX I/O Module | Allen-Bradley | 32 Digital Inputs


Only 10 left - Selling fast

PRODUCT SKU : 1794-TB32

PRODUCT TYPE : Digital Input Terminal Base

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The Allen-Bradley 1794-TB32 is a high-capacity FLEX I/O terminal base designed to accommodate 32 current sinking digital input channels. It delivers reliable signal acquisition and system integration for modular control networks. Compatible with various terminal bases, this unit is engineered to ensure precise, isolated communication between field devices and controllers.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model / Part Number: 1794-TB32

  • Product Type: FLEX I/O Digital Input Module / Terminal Base

  • Number of Inputs: 32, current sinking

  • Recommended Terminal Bases: 1794-TB32, 1794-TB32S, 1794-TB62DS, 1794-TB62EXD4X15

  • Nominal Input Impedance: 22.2 kΩ

  • Isolation Voltage: 50 V continuous, Basic Insulation; type tested at 2121 V DC for 2 s (field side to system)

  • Channel Isolation: No isolation between individual channels

  • FlexBus Current: 25 mA @ 5 V DC

  • Max Power Dissipation: 6.0 W @ 31.2 V DC

  • Max Thermal Dissipation: 20.47 BTU/hr @ 31.2 V DC

  • Terminal Base Screw Torque: Determined by installed terminal base

  • External DC Supply Voltage: 24 V DC nominal

  • Indicators: 32 yellow status LEDs for field side monitoring

  • Dimensions (L x W x H): 6.9 × 9.4 × 9.4 cm

  • Weight: 2 kg

Applications
Suitable for distributed digital input collection in large-scale automation systems, process control, and remote monitoring. Ideal for use with ControlLogix or CompactLogix networks requiring high-channel density and reliable field communication.

FAQ
Q: How many input channels does 1794-TB32 support?
A: This terminal base accommodates 32 current sinking digital inputs.

Q: Can this unit isolate individual channels?
A: No, individual channels are not isolated; isolation is provided between the field and system side.

Q: Which terminal bases are compatible with this module?
A: Compatible with 1794-TB32, 1794-TB32S, 1794-TB62DS, and 1794-TB62EXD4X15.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more