Product Overview

The Allen Bradley 1794-AENTRXT serves as a high-performance communication interface for the FLEX I/O™ platform. This adapter connects up to eight FLEX I/O modules to an EtherNet/IP network, enabling seamless data exchange between field devices and Logix-based controllers. As an "XT" version, it features conformal coating to withstand harsh industrial environments. We guarantee this unit is 100% brand new and original, ensuring maximum network uptime and resistance to environmental contaminants.

Technical Specifications

The 1794-AENTRXT combines high-speed data transmission with robust electrical specifications:

Feature Specification
Network Protocol EtherNet/IP
Ethernet Ports 2 (Supports DLR and Linear Topologies)
Data Rate 10/100 Mbps (Auto-negotiation)
Conformal Coating Yes (Protects against moisture/corrosion)
Input Voltage 19.2 to 31.2 VDC
Enclosure Rating Open-style
Dimensions 3.8cm x 9cm x 13cm
Net Weight 0.56 lbs (0.26 kg)
Country of Origin United States

Engineering Advantages

  • Fault-Tolerant Network Topology: The dual-port design supports Device Level Ring (DLR) technology. This configuration maintains network connectivity even during a single cable failure, preventing costly production shutdowns.

  • Extreme Environment Resilience: Factory-applied conformal coating shields the internal circuitry from humidity, dust, and corrosive vapors. This makes the 1756-AENTRXT ideal for wastewater treatment, oil and gas, and chemical processing facilities.

  • Simplified Hardware Integration: The adapter mounts directly onto a 1794-TB3 or 1794-TB3S terminal base. This modular approach reduces wiring complexity and allows for rapid replacement without disturbing existing field connections.

  • Flexible Power Management: The wide input voltage range (19.2 to 31.2 VDC) accommodates fluctuating industrial power supplies, ensuring stable communication during minor voltage sags.

  • Space-Efficient DIN Rail Mounting: The compact form factor optimizes rail space in high-density control cabinets. The adapter efficiently manages up to 8 I/O modules, centralizing data collection in a single, small-footprint node.

FAQs

  • What is the significance of the "XT" suffix in 1794-AENTRXT?

    The "XT" stands for Extended Environment. This module includes conformal coating and often supports a wider temperature range than the standard 1794-AENTR version, making it suitable for more demanding industrial locations.

  • Does this adapter support the Device Level Ring (DLR) protocol?

    Yes. The two Ethernet ports allow you to configure the module in a DLR ring or a linear daisy-chain topology, providing hardware-level redundancy for your communication network.

  • Is this a 100% brand new, factory-sealed unit?

    Absolutely. We supply only brand new and original 1794-AENTRXT modules. Every unit carries the verified UPC 885630106151 and ships in original Allen Bradley packaging to ensure authenticity.

  • How many I/O modules can a single 1794-AENTRXT control?

    A single adapter supports up to 8 FLEX I/O modules in any combination of digital, analog, or specialty modules, provided the total backplane current does not exceed the adapter's limits.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more