Product Description

The Allen-Bradley 1783-BMS06TL Stratix 5700 is a compact, industrial-grade managed switch designed to provide secure and reliable Ethernet connectivity. With six Fast Ethernet RJ45 ports, wide voltage tolerance, and rugged environmental ratings, it is well-suited for demanding automation networks.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line Stratix 5700

  • Product Type 6-Port Managed Ethernet Switch

  • Part Number 1783-BMS06TL

  • Weight 2.50 lbs (1.13 kg)

  • Port Type Fast Ethernet RJ45 (6 ports)

  • Power Dissipation 15 W maximum

  • Isolation Voltage 50 V

  • Rated Voltage 12–48 VDC

  • Rated Current 0.5–2 A (depending on supply voltage)

  • Wire Size for DC Power Connection 0.5–0.8 mm²

  • IP Rating IP30 (indoor use, protected installation)

  • Operating Temperature Range -40 °C to +60 °C

  • Storage Temperature Range -40 °C to +100 °C

  • Relative Humidity 5–95% non-condensing

Application Scenarios

  • Industrial Ethernet networking for PLCs, HMIs, and controllers

  • Harsh environments requiring extended temperature tolerance

  • Compact control panels where space-efficient managed switches are needed

  • Secure automation networks with managed switch functionality

FAQ

Q: How many Ethernet ports does the 1783-BMS06TL provide?  A: It offers six Fast Ethernet RJ45 ports.

Q: What is the operating voltage range?  A: The switch operates between 12 and 48 VDC.

Q: Can this switch be used in outdoor environments?  A: No, it is rated IP30 and intended for protected indoor installations.

Comparison with Similar Models

  • 1783-BMS10CGA: Provides 10 ports with Gigabit capability.

  • 1783-BMS06SA: Similar 6-port configuration but with different management features.

  • 1783-BMS06TL: Balanced option with six Fast Ethernet ports, compact size, and wide voltage range.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more