PRODUCT SKU : 1440-RMA00-04RC

PRODUCT TYPE : Master Relay Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1440-RMA00-04RC is a Master Relay Module from the XM-440 series, designed to provide versatile control with four DPDT relays. Each relay can be configured as normally energized or de-energized and supports latching or non-latching operation. With adjustable time delay, local, remote, or digital reset options, this module offers precise and flexible relay control for industrial automation applications. Its compact footprint and low heat output make it suitable for space-constrained panels.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model Number: 1440-RMA00-04RC

  • Product Type: Master Relay Module

  • Series: XM-440

  • Relay Type: 4 × DPDT (2 Form C) relays

  • Contact Rating: 250V AC, 3A resistive, 50/60 Hz

  • Failsafe Options: Normally energized or de-energized

  • Latching Options: Latching or Non-latching

  • Time Delay: 0–25.5 seconds, adjustable in 100 ms increments

  • Reset Methods: Local, remote, or digital command

  • Power Supply: 24V DC, 200 mA max

  • Power Consumption: 3.4 W (11.6 BTU/hr)

  • Heat Production: 3.4 W (11.6 BTU/hr)

  • Module Dimensions: Height 97 mm × Width 94 mm × Depth 94 mm (3.8 × 3.7 × 3.7 in)

  • Screw Torque: 7 lb-in (0.6 Nm)

  • Mounting: Standard DIN rail or panel mount (verify system compatibility)

Application Scenarios

  • Centralized relay control for machine automation

  • Switching high-voltage signals in control panels

  • Systems requiring adjustable time delays and flexible reset configurations

  • Industrial processes needing reliable failsafe operation

FAQ

Q: How many relay channels does the XM-440 module provide?
A: It provides 4 DPDT (2 Form C) relays.

Q: Can the relays be latched or non-latched?
A: Yes, the module supports both latching and non-latching configurations.

Q: What is the maximum time delay setting?
A: The delay can be adjusted from 0 to 25.5 seconds in 100 ms increments.

Q: What is the required supply voltage?
A: 24V DC at a maximum of 200 mA.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more