Product Details

The Schneider Electric V255-073749, also cataloged as the V255-073749 Feeder and Motor Protection Relay, operates as a dedicated hardware component for selective current monitoring and automated breaker trip execution within industrial power distribution networks. It samples phase vector magnitudes to isolate electrical anomalies directly at the hardware layer.

Hardware Specifications

Parameter Specification
Model V255-073749
Brand Schneider Electric
Origin Finland
Weight 0.3 kg (0.66 lbs)
Dimensions 12.0 cm x 10.5 cm x 13.0 cm
Operating Temp -10 to +55 deg C standard industrial limits
Power Consumption Standard auxiliary operational load
Series VAMP 255
Product Type Protection Relays
Mounting Type Flush panel mounting configuration
Protection Functions Overcurrent, Earth Fault, Motor, Capacitor Bank, and Busbar Protection

Profinet / EtherNet/IP Deterministic Networks and I/O Density Scaling

The VAMP 255 platform executes real-time telemetry streaming over deterministic Profinet and EtherNet/IP networks to synchronize power quality data with process controllers. The internal processing core scales hardware sampling density across current inputs, maintaining deterministic scanning speed without delaying critical overcurrent trip decisions. Firmware flash compatibility ensures fault-event records and setting matrices remain intact during system power cycles.

Frequently Asked Questions

Q: What panel preparation is required for the flush mount enclosure?

A: Cut a rectangular panel cutout corresponding to the 12.0 cm x 10.5 cm x 13.0 cm physical dimensions, ensuring adequate rear clearance for terminal block wiring and grounding straps.

Q: How does the processing core maintain coordination with downstream circuit breakers?

A: The onboard micro-controller samples high-density current vectors continuously. Trip logic runs locally on the hardware matrix to initiate contact closure in milliseconds, bypassing network transfer delays.

Q: What primary equipment functions can be assigned to the protective channels?

A: The relay logic can be configured to protect feeder lines, electric motors, capacitor banks, and distribution busbars against earth faults and overcurrent conditions.

Field Installation Guidelines

  1. Cut the designated mounting opening on the enclosure door and insert the relay from the front face.
  2. Secure the flush-mounting brackets from the rear of the panel, tightening the retaining screws evenly to prevent panel distortion.
  3. Connect the protective earth (PE) ground terminal directly to the central panel earth bus using a short, high-strand copper conductor.
  4. Route phase CT secondary wiring to the dedicated rear terminal blocks, verifying correct current transformer polarity before energizing.
  5. Terminate auxiliary power and communication lines in separate wire channels away from high-voltage current measurement leads.
  6. Verify terminal screw tightness across all active contact blocks prior to applying control power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more