Product Details

The Schneider Electric LUCB05BL, also cataloged as the LUCB Advanced Control Unit, operates as a dedicated hardware component for 3-phase motor protection and thermal overload execution within TeSys Ultra power bases.

Hardware Specifications

Parameter Specification
Model LUCB05BL
Brand Schneider Electric
Origin France
Weight 113 g (0.113 kg)
Dimensions 45 mm x 66 mm x 60 mm (W x H x D)
Operating Temp -25 to +70 deg C
Power Consumption Heat dissipation: 2 W (with LUB12), 3 W (with LUB32/LUB38)
Rated Operational Voltage [Ue] 690 V AC (40 to 60 Hz)
Control Circuit Voltage [Uc] 24 V DC (Limits: 20 to 27 V DC operational, 14.5 V DC drop-out)
Motor Current Adjustment Range 1.25 to 5 A
Thermal Overload Class Class 10 (40 to 60 Hz, -25 to 70 deg C)
Tripping Threshold 14.2 x Ir +/- 20 %
Motor Power Rating 1.5 kW at 400-440 V AC, 2.2 kW at 500 V AC, 3 kW at 690 V AC
Control Current Consumption Closing: 130 mA (LUB12), 220 mA (LUB32/38); Sealed: 60 mA (LUB12), 80 mA (LUB32/38)
Insulation Voltage [Ui] 690 V (IEC 60947-6-2), 600 V (UL 60947-4-1 / CSA C22.2 No 60947-4-1)
Ingress Protection IP20 (front panel and wired terminals), IP40 (front panel outside connection zone)

Industrial Control & Bus Communication Characteristics

The LUCB05BL advanced control unit attaches directly via front-face plug-in mounting to LUB power bases and LU2B reversing contactor breakers. Internal current-sensing transformers provide phase failure sensitivity, phase imbalance protection, earth fault detection, and manual reset functions. Communication interface capabilities support real-time motor diagnostic transmission across Profinet and EtherNet/IP deterministic networks, maintaining backplane bus communication velocity and firmware flash compatibility across integrated starter configurations.

Frequently Asked Questions

Q: What are the control coil voltage operational thresholds for the LUCB05BL unit?

A: The rated control circuit voltage is 24 V DC, operating within strict limits of 20 to 27 V DC during active state execution and dropping out at 14.5 V DC.

Q: Which power bases and contactors are physically compatible with this control module?

A: The LUCB05BL plug-in module interfaces directly with LUB12, LUB32, LUB38, LUB120, LUB320, and LUB380 power bases, as well as LU2B12BL, LU2B32BL, and LU2B38BL reversing contactor breakers.

Q: What opening and closing times occur when the control unit acts on a power base?

A: Operating response times are rated at 35 ms for circuit opening and 70 ms for circuit closing across LUB12, LUB32, and LUB38 assemblies.

Field Installation Guidelines

  • Plug-In Mounting: Align the LUCB05BL unit with the front-face connector slot of the unpowered LUB or LU2B base unit and push firmly until the locking mechanism fully seats.
  • Control Circuit Wiring: Connect 24 V DC control supply leads to the designated control terminals. Ensure control circuit voltage remains between 20 V DC and 27 V DC during peak inrush (up to 220 mA) to prevent contact chatter.
  • Thermal Current Setting: Adjust the front dial to match the exact full-load current (FLA) of the connected 3-phase motor within the 1.25 A to 5 A scaling range before applying main line voltage up to 690 V AC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more