MNB-1000 Schneider Electric MicroNet BACnet Plant Controller
MNB-1000 Schneider Electric MicroNet BACnet Plant Controller
MNB-1000 Schneider Electric MicroNet BACnet Plant Controller

MNB-1000 Schneider Electric MicroNet BACnet Plant Controller


Only 10 left - Selling fast

PRODUCT SKU : MNB-1000

PRODUCT TYPE : Plant Controllers

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Schneider Electric MNB-1000, also cataloged as the MNB-1000 BACnet Plant Controller, operates as a dedicated hardware component for direct physical I/O execution and network routing within BACnet building automation systems. It interfaces with field instrumentation using 12 universal inputs, 4 digital inputs, 8 universal outputs, and 8 digital outputs (Triacs) while handling native BACnet/IP, BACnet Ethernet, and MS/TP protocols.

Hardware Specifications

Parameter Specification
Model MNB-1000
Brand Schneider Electric
Origin France
Dimensions 213 mm x 278 mm x 58 mm
Operating Temp -40 to +60 deg C
Power Consumption 50 VA at 24 VAC
Product Type BACnet Plant Controllers
Input Power 20.4 to 30 VAC, 50/60 Hz
Operating Humidity 5% to 95% non-condensing
Universal Inputs 12 channels
Digital Inputs 4 channels
Universal Outputs 8 channels
Digital Outputs 8 Triac outputs
Communication Protocols Native BACnet/IP, BACnet Ethernet, BACnet MS/TP
Local Expansion Sensor Link (S-Link) for remote I/O and sensor interfaces

Ethernet Determinism and I/O Density Scaling

The MicroNet platform incorporates dual Ethernet ports to manage local network routing and deterministic traffic distribution across BACnet networks. Designed for high I/O density scaling, the MNB-1000 maintains predictable packet processing latencies during simultaneous BACnet/IP routing and MS/TP master loop token passing. Internal firmware flash compatibility ensures synchronized parameter storage across distributed control nodes without corrupting real-time physical point updates.

Frequently Asked Questions

Q: What power input range is required for the internal electronics, and how is it fused?

A: The module operates on 20.4 to 30 VAC at 50/60 Hz, drawing up to 50 VA at nominal 24 VAC. Field wiring must incorporate external protection sized for the total transformer load, including active S-Link peripheral connections.

Q: How does the S-Link interface expand hardware IO capabilities?

A: The proprietary Sensor Link (S-Link) bus allows point-to-point communication with remote sensors and room display units, offloading local universal input channels for primary mechanical equipment monitoring.

Q: Are the 8 digital outputs dry relay contacts or solid-state switches?

A: The 8 digital outputs are solid-state Triac switches designed for AC control circuits. They must be powered from an external AC source consistent with standard HVAC actuator pilot control circuits.

Field Installation Guidelines

  1. Mount the unit vertically inside a grounded control enclosure using standard mounting hardware through the designated mounting holes on the base plate.
  2. Maintain clearance surrounding the housing to allow natural convective heat dissipation across the ambient operating range of -40 to +60 deg C.
  3. Wire the 24 VAC power supply to the dedicated power terminals, ensuring correct transformer sizing for a minimum load of 50 VA.
  4. Terminate BACnet MS/TP communication wiring using shielded twisted-pair cabling. Ground the shield at one end only to prevent ground loops across network nodes.
  5. Connect field sensors and actuators to the universal input and Triac output terminal blocks according to the programmed WorkPlace Tech Tool point database configuration.
  6. Verify all low-voltage signal wiring and S-Link bus connections before energizing the 24 VAC main input terminal block.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more