Product Details
Product Overview
The Schneider Electric BMXAMM0600 executes simultaneous analog signal acquisition and process instrumentation control within the Modicon X80 automation environment. This compact, high-level mixed module integrates 4 analog input channels and 2 analog output channels into a single physical card slot. By combining both functions, the module directly interfaces with field transmitters, control valves, flow sensors, and variable frequency drives, acting as a space-saving multi-signal interface for standalone machine control, pumping stations, and local processing loops.
Technical Specifications
| Parameter | Technical Specification Value |
| Manufacturer | Schneider Electric |
| Model | BMXAMM0600 |
| Range of Product | Modicon X80 |
| Product Type | High-Level Mixed Analog Input/Output Module |
| Condition | 100% Brand New Original |
| Analogue Input Count | 4 high-level channels (Non-isolated between channels) |
| Analogue Input Types |
Current: 0...20 mA, 4...20 mA Voltage: +/- 10 V, 0...10 V, 0...5 V, 1...5 V |
| Analogue Input Resolution |
12 bits (Current & 0...5V/1...5V) 13 bits (0...10V) 14 bits (+/- 10V) |
| Analogue Output Count | 2 high-level channels |
| Analogue Output Types |
Current: 0...20 mA, 4...20 mA Voltage: +/- 10 V |
| Analogue Output Resolution |
11 bits (Current) 12 bits (+/- 10 V) |
| Bus Galvanic Isolation |
1400 V DC between channels and backplane bus/ground 750 V DC between I/O channel groups |
| Input Impedance (Current) | 250 Ohm (backed by 0.1% precision internal resistor) |
| Conversion & Read Times |
Input Read: 5 ms (for 4 channels) Output Conversion: <= 2 ms |
| Mean Time Between Failures | 1,400,000 Hours (MTBF) |
| Physical Wiring Connection | Single 20-way connector |
| Product Net Weight | 0.342 lb (0.155 kg) |
Engineering Advantages
-
Footprint Consolidation via Mixed Architecture: Small control enclosures offer highly restricted mounting spaces. The BMXAMM0600 resolves this mechanical constraint by grouping 4 distinct input loops and 2 output loops into a single 1.3-inch wide module slot. This integration eliminates the need to buy separate input and output cards, reducing total rack dimensions and shrinking hardware bills of materials.
-
Robust Bus-Level Voltage Protection: Industrial field wiring frequently exposes electronics to inductive spikes. While sharing local grounds within the module, the BMXAMM0600 protects your central PAC processor by maintaining a 1400 V DC galvanic isolation barrier between all physical channels and the backplane bus, and a 750 V DC isolation layer between the input and output groups.
-
Flexible Multi-Range Field Adaptation: Different sensor types utilize varying electrical standards. This module accepts mixed voltage and current formats simultaneously, supporting +/- 10 V, 0...10 V, 0...5 V, 1...5 V, 0...20 mA, and 4...20 mA. Field technicians change these ranges on a per-channel basis inside the EcoStruxure programming software without manipulating physical switches.
-
Ruggedized Fault Handling and Fallbacks: Complete communication loss can cause dangerous process behavior. The module incorporates configurable fallback modes that force the 2 analog outputs to hold their last valid value or ramp immediately to a predefined safe milliamp/voltage level, safeguarding physical downstream valves and motors.
-
Firmware-Based Digital Filtering: High-frequency ambient electromagnetic interference (EMI) degrades sensor reading precision. Built-in first-order digital filtering, executed natively by the internal firmware, suppresses high-frequency line ripple to deliver stabilized, noise-free numerical data directly to the controller memory.
FAQs
-
Is this BMXAMM0600 mixed analog module a brand new original unit?
Yes. We supply this component strictly as a 100% brand new, original factory-sealed unit. It arrives inside its authentic Schneider Electric box with factory warranties, quality certifications, and protective materials intact.
-
Does this module feature point-to-point isolation between the individual inputs?
No. The 4 analog input channels are non-isolated from each other and share a common internal ground loop. However, the module provides a comprehensive 1400 V DC isolation barrier between the I/O channels as a collective group and the internal backplane bus.
-
What happens if a field device feeds an excessive current or voltage to the input channel?
The module possesses robust, built-in protection parameters. It sustains permitted overloads up to +/- 30 mA in current modes and up to +/- 30 V in voltage configurations without burning out the 0.1% precision internal conversion resistor.
-
How does the card signify real-time circuit status to field operators?
The front face features a clear, multi-LED local signaling array. A green RUN LED indicates active module operation, a red ERR LED tracks internal hardware problems, an I/O fault light signals field wiring errors, and individual green LEDs provide diagnostic status for each of the active channels.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.