Skip to content

What are you looking for?


You may also like

DeltaV | Emerson KL2101X1-BA1 CHARMs Dry Contact Discrete Input ModuleDeltaV | Emerson KL2101X1-BA1 CHARMs Dry Contact Discrete Input ModuleDeltaV | Emerson KL2101X1-BA1 CHARMs Dry Contact Discrete Input Module
DeltaV | Emerson KL2101X1-BA1 CHARMs Dry Contact Discrete Input Module
DeltaV | Emerson KL2101X1-BA1 CHARMs Dry Contact Discrete Input Module
DeltaV | Emerson KL2101X1-BA1 CHARMs Dry Contact Discrete Input Module

DeltaV | Emerson KL2101X1-BA1 CHARMs Dry Contact Discrete Input Module


Only 10 left - Selling fast

PRODUCT SKU : KL2101X1-BA1

PRODUCT TYPE : Discrete Input Module

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Emerson KL2101X1-BA1 functions as a high-precision, single-channel Dry Contact CHARM (Characterized Module) designed for the DeltaV Electronic Marshalling architecture. This specialized discrete input card monitors unpowered, open-voltage field switch contacts such as limit switches, pushbuttons, and auxiliary relay interlocks. By generating an isolated internal sensing voltage, the hardware safely monitors the state of field circuits without requiring external field power distribution blocks. We guarantee this discrete input CHARM module arrives in 100% brand new, original factory-sealed condition.

Technical Specifications

Parameter Specification Value
Manufacturer Emerson Automation Solutions
Product Line DeltaV Electronic Marshalling
Model / Part Number KL2101X1-BA1 (Assembly: KL2101X1BA1)
Functional Classification I/O Card / PLC Module / Machine Control
Sensing Type Dry Contact Discrete Input (Open Voltage Sensing)
Local Bus Power Demand 26.4 VDC Maximum at 32 mA
Field Circuit Output 24 VDC at 10 mA Current Loop
Module Shipping Weight 0.99 lbs (0.45 kg)

Engineering Advantages

  • Elimination of Cross-Talk via Component-Level Electronic Marshalling: This modular CHARM snaps directly onto the field terminal block, pairing field wiring instantly with its dedicated controller path. This localized architecture removes traditional cross-marshalling wire bundles, stripping out high-frequency electromagnetic cross-talk and reducing cabinet wiring labor by up to 50%.

  • Self-Powered Open-Voltage Interrogation Loop: The internal circuitry pushes a low-energy 24 VDC at 10 mA testing current through the field circuit. This features allows the module to detect mechanical switch transitions across floating, unpowered contacts safely, removing the expense and failure points of adding external power supplies inside field junction boxes.

  • Low Current Demand Backplane Efficiency: Drawing only 32 mA from the 26.4 VDC local bus rail, the card minimizes systemic power drain across large-scale control nodes. This low thermal footprint prevents the buildup of internal panel heat, allowing engineers to dense-pack 0.99-lb modules tightly inside sealed, unventilated enclosures.

  • Rapid Fault Isolation and Inductive Spike Shunting: The discrete circuit integrates optical isolation components that shield the sensitive DeltaV local bus from incoming high-voltage spikes. If an inductive field wire shorts out due to lightning or insulation wear, the CHARM confines the electrical failure to its individual channel, preventing widespread backplane corruption.

FAQs

  • Does this KL2101X1-BA1 CHARM arrive inside its original packaging?

    Yes. We sell this automation component exclusively as a 100% brand new, factory-original hardware piece. The module remains completely sealed inside its untouched Emerson anti-static protective wrapping inside the original corporate box, keeping all asset-tracking barcodes and factory serial labels intact.

  • Can I plug this module into an active system without turning off the power?

    Yes. The Electronic Marshalling baseboard supports full hot-swapping functionality. Maintenance personnel can safely remove an aging unit and snap this brand new CHARM into its slot on a live carrier rack without disturbing power rails or dropping communications on adjacent channels.

  • What happens if I accidentally apply external 120 VAC power to this dry contact loop?

    External line voltages will overload the 24 VDC, 10 mA field circuit and compromise the internal opto-isolator. This card requires strictly unpowered mechanical contacts. If your field device outputs a hot voltage signal, you must source a different CHARM model type or install an interposing isolation relay.

  • Why does a single-channel CHARM weigh 0.99 lbs in the documentation?

    The 0.99 lbs shipping specification reflects the industrial-grade, heavy-duty protective structural housing and dense packaging materials that Emerson utilizes to safeguard the precision internal solid-state electronics from damage during transit and warehouse handling.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more