Hardware Specifications

Parameter Specification
Model 51305482-505
Brand Honeywell
Origin USA
Dimensions 5 meters (LAN B version)
Operating Temp -40 to +85 deg C
Power Consumption Passive wiring component
Component Type Industrial Ethernet Cable / 100 Base-T LAN Cable
Conductor Material Copper
Conductor Gauge 20 AWG
Insulation Material PVC
Rated Voltage 300-600 V
Rated Current 5 A
Shielding Multi-conductor overall industrial shielding

FOUNDATION Fieldbus / Profibus PA Connectivity

The 51305482-505 100 Base-T Ethernet cable establishes reliable physical layer links between local control network nodes and upper-level DCS architectures. When routed adjacent to field instrumentation buses utilizing FOUNDATION Fieldbus or Profibus PA protocol configurations, the high-density shielding layer attenuates industrial electromagnetic noise and cross-talk.

This signal integrity prevents packet corruption and latency spikes across the TPNB LAN B network, ensuring continuous telemetry synchronization between system controllers and process network gateways.

Frequently Asked Questions

Q: What network interface protocols are supported by the 51305482-505 cable assembly?

A: The cable assembly is engineered for 100 Base-T Ethernet communications and supports data exchange across Honeywell TPNB LAN B networks.

Q: What conductor size and voltage rating are specified for this Ethernet cable?

A: The assembly utilizes 20 AWG multi-conductor copper wiring rated for operation between 300 V and 600 V.

Q: Can this industrial Ethernet cable withstand harsh cabinet thermal environments?

A: Yes, the cable jacket and PVC insulation are specified for continuous operation across an extended temperature range of -40 to +85 deg C.

Field Installation Guidelines

  • De-energize connected network interface cards or switch ports before mating or unmating Ethernet connectors.
  • Ensure maximum tensile load and minimum bending radius specifications are respected during conduit pulling to protect the 20 AWG conductor core.
  • Route the industrial Ethernet cable along dedicated communication wireways, maintaining separation from high-voltage AC power distribution.
  • Connect the cable shield drain directly to the cabinet protective earth (PE) grounding bar to ensure effective high-frequency noise suppression.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more