Skip to content

What are you looking for?


You may also like

Honeywell TC-IAHI61 High-Level Analog Input ModuleHoneywell TC-IAHI61 High-Level Analog Input ModuleHoneywell TC-IAHI61 High-Level Analog Input Module
Honeywell TC-IAHI61 High-Level Analog Input Module
Honeywell TC-IAHI61 High-Level Analog Input Module
Honeywell TC-IAHI61 High-Level Analog Input Module

Honeywell TC-IAHI61 High-Level Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : TC-IAHI61

PRODUCT TYPE : High-Level Analog Input Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-level analog signal acquisition in Honeywell Experion PKS and TDC 3000 DCS platforms, the Honeywell TC-IAHI61 (TC-IAHI61 High-Level Analog Input Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model TC-IAHI61
Brand Honeywell
Origin USA
Weight Approx. 1.5 kg
Dimensions Not specified
Operating Temp 0 deg C to 60 deg C
Power Consumption 4.1 W maximum
Module Type High-Level Analog Input (HLAI) Module
Compatible Systems Honeywell Experion PKS, TDC 3000 DCS
Number of Channels 16 independent analog input channels
Input Signal (Voltage) +/-10.25 V, 0 to 10.25 V, 0 to 5.125 V
Input Signal (Current) 4-20 mA, 0 to 20.5 mA via internal 250 ohm resistor
A/D Conversion Resolution 16-bit
Module Update Rate 250 ms
Sampling Capability Up to 1 kHz transient capture rate
Voltage Input Impedance Greater than 1.0 Mohm
Current Input Impedance 249 ohm nominal
Channel Bandwidth 20 Hz (-3 dB)
RFI Immunity Less than 2% error of range at 10 V/m, 27 to 1000 MHz
Isolation Voltage 2550 VDC for 1 second (User to System)
Compatible Terminal Block TC-TBCH 36-position terminal block

Process Signal Isolation and 4-20 mA HART Loop Protocol

The Honeywell TC-IAHI61 integrates high-level analog measurement circuits for direct connection to field transmitters across 16 independent channels. The input architecture provides channel-to-channel isolation and galvanic user-to-system isolation up to 2550 VDC to prevent common-mode electrical interference and ground loop cross-talk. Signal processing paths support full 4-20 mA HART loop protocol compatibility at the physical interface, converting field voltage and current loops into 16-bit digital values while maintaining signal integrity across the Experion PKS and TDC 3000 backplane interfaces. Integrated diagnostic circuits perform open-circuit detection to identify field wiring faults in real time.

Frequently Asked Questions

Q: Does the TC-IAHI61 support mixed analog input types on the same module?

A: Yes, each of the 16 channels can be configured independently for either voltage ranges (+/-10.25 V, 0-10.25 V, 0-5.125 V) or current signals (4-20 mA, 0-20.5 mA).

Q: What isolation voltage level does the TC-IAHI61 provide?

A: The module features user-to-system electrical isolation rated and tested at 2550 VDC for 1 second.

Q: Which terminal block is required for external field wiring connections?

A: The module directly interfaces with the Honeywell TC-TBCH 36-position terminal block assembly.

Field Installation Guidelines

  1. Confirm electrostatic discharge (ESD) prevention measures are in place and wear a grounded wrist strap prior to handling the module.
  2. Insert the module into the designated slot of the Honeywell Experion PKS or TDC 3000 chassis until the backplane connectors fully seat.
  3. Align and attach the TC-TBCH 36-position terminal block, securing all mounting hardware to ensure continuous contact.
  4. Route field analog signal cables through low-voltage cable channels, keeping them separate from AC power and high-voltage switching lines.
  5. Connect cable shield drain wires directly to the designated enclosure earth grounding bar in accordance with site grounding standards.
  6. Verify field loop polarity and ensure transmitter output range settings match the configured voltage or current parameters before energizing the loop.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more