The GE UR77H Inter-Relay Communications Module, part of the Multilin Universal Relay (UR) series, is engineered to enable high-speed fiber-optic communication between UR relays. It supports teleprotection, fast tripping, and coordinated control, ensuring secure and reliable data exchange in modern power system protection schemes.

Technical Specifications

  • Manufacturer: General Electric (GE)

  • Model: UR77H

  • Type: Inter-Relay Communications Module

  • Function: Relay-to-relay communications

  • Communication Standard: IEEE C37.94

  • Transmission Medium: Multimode fiber optic

  • Wavelength: 820 nm

  • Number of Channels: 2

  • Indicators: LED status indicators for diagnostics

  • Mounting Orientation: Horizontal installation within UR chassis

  • Dimensions: 280 mm × 115 mm × 45 mm

  • Weight: 0.6 kg

  • Country of Origin: USA

Key Features

  • Enables exchange of digital status and analog values between UR relays

  • Supports fast tripping and teleprotection applications

  • Noise-immune fiber-optic communication for reliable performance

  • Compact modular design for seamless integration into UR systems

  • Built for demanding industrial and utility environments

Applications

  • Substation automation requiring relay-to-relay communication

  • Power system protection and coordination

  • Teleprotection schemes for transmission lines

  • Industrial control systems with distributed relay networks

FAQ

  • Q: What communication standard does the UR77H support?  A: It complies with IEEE C37.94 for inter-relay communication.

  • Q: How many channels are available?  A: The UR77H provides 2 fiber-optic channels.

  • Q: What wavelength does the module operate at?  A: It uses 820 nm multimode fiber optic transmission.

  • Q: Is the UR77H suitable for teleprotection?  A: Yes, it is specifically designed for fast tripping and teleprotection applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more