Overview

The 1785-LT2 from Allen-Bradley is a high-performance processor module within the PLC-5 Classic series, designed for versatile industrial control applications. It supports extensive local and remote I/O configurations and provides embedded communication channels including Data Highway Plus (DH+) and RS-232. This module is mounted in the left-most slot of a 1771 I/O chassis and delivers reliable control for medium-to-large automation systems.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PLC-5 Classic

  • Part Number: 1785-LT2

  • Module Type: Processor

  • Supported Local I/O: Up to 4 racks (1 resident rack)

  • Supported Remote I/O: Up to 3 remote racks

  • Total I/O Capacity: 512 inputs / 512 outputs (expandable with modules)

  • Maximum Total I/O: 3072 points (any mix)

  • Analog I/O: Up to 3072 points

  • Embedded RAM: 6K Words (expandable to 14K Words)

  • Memory Modules Supported: 1785-MR (4K RAM), 1785-MS (8K RAM), 1785-MJ (8K EEPROM)

  • Battery: 1770-XY

  • Program Scan Time: 2 ms per K words (bit logic), 8 ms per K words (typical)

  • Built-in Communication: One DH+ channel, one local/remote I/O scanner adapter

  • Hardware Addressing: 2-slot, 1-slot, ½ slot

  • Control Coprocessor Expansion: Supported

  • RS-232-C/422-A/423-A Ports: 1

Performance & Communication

  • I/O Scan Time per Rack:

    • 10 ms @ 57.6 kbits/s

    • 7 ms @ 115.2 kbits/s

    • 3 ms @ 230.4 kbits/s

  • Maximum I/O Chassis Total: 93

  • Max Extended Local Chassis: 0

  • Max Universal Remote Chassis: 32 per I/O Link

Installation & Mounting

  • Location: Left-most slot in 1771 I/O chassis

  • Module Keying: Between 40–42 and 54–56

  • Weight: 3.06 lbs (1.39 kg)

Applications

  • Industrial automation requiring scalable I/O control

  • Medium to large PLC-5 system integration

  • Remote I/O management with high-speed DH+ communication

  • Analog and digital I/O intensive processes

FAQ

Q: Can 1785-LT2 support remote I/O racks?
A: Yes, up to 3 remote racks are supported.

Q: What memory expansion options are available?
A: Supports 4K, 8K RAM modules (1785-MR, 1785-MS) and 8K EEPROM (1785-MJ).

Q: What communication channels are built-in?
A: Includes one DH+ port and one local/remote I/O scanner adapter.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more