PRODUCT SKU : 2711-T10C1

PRODUCT TYPE : Touch Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711-T10C1 belongs to the PanelView 1000 Standard series, providing a high-performance interface for complex machine control. This terminal features a 10.1-inch Color Active Matrix TFT display that delivers sharp 640 x 480 resolution for real-time process monitoring. As a "Touch" model, it utilizes an analog resistive touchscreen rated for 1 million actuations, allowing operators to interact directly with graphical screen objects. This specific unit supports Remote I/O (RIO) communication, making it a critical component for maintaining or repairing established industrial networks.

Technical Specifications

Feature Specification Details
Manufacturer Allen Bradley / Rockwell Automation
Model 2711-T10C1
Display Size/Type 10.1-inch Color Active Matrix
Operator Input Analog Resistive Touchscreen
Communication Ports Remote I/O (RIO); RS-232 (Printer Port)
Input Voltage 85–264V AC (Wide Range)
Resolution 640 x 480
Internal Memory 310 KB Runtime; 1008 KB Nonvolatile
Protection Rating NEMA Type 12/13, 4X (Indoor), IP65
Condition 100% Brand New Original

Engineering Advantages

  • Robust Network Integration: The integrated Remote I/O (RIO) port allows the 2711-T10C1 to connect directly to PLC-5 and SLC 500 controllers over long distances. This eliminates the need for expensive network architecture overhauls in legacy systems.

  • High-Visibility Interface: The Active Matrix display offers superior brightness and wider viewing angles compared to passive screens. It ensures that operators clearly identify alarm conditions and process variables from various positions on the factory floor.

  • Wide Power Flexibility: The universal AC power supply (85–264V AC) handles significant voltage fluctuations without requiring external stabilizers. This makes it ideal for facilities with inconsistent power quality.

  • Ruggedized Environmental Seal: The terminal meets NEMA 4X and IP65 standards when panel-mounted. This seals the internal electronics against dust, oil, and water spray, ensuring longevity in wash-down or high-debris environments.

  • Tactile Precision: The touchscreen supports up to 1 million presses, providing a reliable long-term input method that replaces failure-prone physical pushbuttons and simplifies control panel layouts.

FAQs

  • Is this 2711-T10C1 unit truly "Brand New"?

    Yes. Despite the manufacturer’s discontinued status for this series, we supply this unit as 100% Brand New in its original factory packaging. This ensures the 50,000-hour LED backlight life remains fully intact for your critical operations.

  • Can I print data logs directly from this terminal?

    Yes. Use the dedicated RS-232 printer port to output alarm lists and reports directly to a compatible serial printer without consuming bandwidth on your primary RIO network.

  • What are the mounting requirements for IP65 protection?

    You must install the terminal into a flat panel surface using the provided mounting levers and ensure the gasket seats properly. This setup maintains the NEMA 4X/IP65 integrity for indoor use.

  • Does this model support touch and keypad input simultaneously?

    No. The 2711-T10C1 is a dedicated touch-only model. If your application requires physical function keys, you would need the "K1" version (e.g., 2711-K10C1).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more