Skip to content

What are you looking for?


You may also like

TK-ODJ161 Digital Output Module | HoneywellTK-ODJ161 Digital Output Module | HoneywellTK-ODJ161 Digital Output Module | Honeywell
TK-ODJ161 Digital Output Module | Honeywell
TK-ODJ161 Digital Output Module | Honeywell
TK-ODJ161 Digital Output Module | Honeywell

TK-ODJ161 Digital Output Module | Honeywell


Only 10 left - Selling fast

PRODUCT SKU : TK-ODJ161

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete output actuation within Honeywell DCS and PLC platforms, the Honeywell TK-ODJ161 (TK-ODJ161 Digital Output Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model TK-ODJ161
Brand Honeywell
Origin Standard Industrial Manufacturing
Weight Approx. 0.3 kg
Dimensions Standard DIN rail modular profile
Operating Temp Standard industrial cabinet range
Power Consumption Low-voltage bus logic powered
Output Channels 16 discrete outputs
Output Voltage 24 VDC
Mounting Type DIN rail compatible

Channel-To-Channel Isolation And Loop Protocol Integrity

The module incorporates electrical isolation between internal control logic and field terminals to suppress transient voltage spikes and protect backplane architecture from field-side disturbances. It supports deterministic switching for 24 VDC industrial loads while maintaining channel isolation integrity. Cold junction compensation (CJC) references and robust circuit design safeguard switching signals against inductive kickback and electromagnetic interference across multi-channel configurations.

Frequently Asked Questions

Q: Can the TK-ODJ161 module be hot-swapped while the rack power is active?

A: No. Power must be isolated from the mounting chassis prior to inserting or removing the digital output module to prevent backplane bus logic latch-up or pin damage.

Q: What specific load types are supported by the 16 discrete output channels?

A: The outputs are rated for standard industrial 24 VDC loads, including control relays, solenoid valves, and indicator actuators.

Field Installation Guidelines

  • Ensure primary cabinet power and field power supplies are locked out and tagged out prior to installation or wiring.
  • Mount the module securely onto standard 35 mm DIN rail, ensuring proper physical clearance for cabinet thermal management.
  • Terminate field wiring firmly to the module terminals, maintaining appropriate torque specifications to prevent loose connections under vibration.
  • Verify output channel functionality and loop continuity via controller diagnostic indicators before returning the system to operational service.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more