Product Description

The TC-IAH161 from Honeywell is a high-level analog input module designed for precise voltage and current measurement across 16 channels. Built for industrial automation, it delivers reliable performance and robust signal integrity for critical control applications.

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: TC-IAH161

  • Product Type: High-Level Analog Input Module

  • Channels: 16

  • Voltage Input Ranges: ±10.25 V, 0–10.25 V, 0–5.125 V

  • Current Input Range: 0–20.5 mA (via internal 250 Ω resistor)

  • Resolution: 16-bit across all ranges

  • Module Publish Rate: 250 ms

  • Input Impedance: Voltage >1 MΩ, Current 249 Ω nominal

  • Channel Bandwidth: 20 Hz (-3 dB)

  • RFI Immunity: <2% of range at 10 V/m, 27–1000 MHz

  • Power Dissipation: 4.1 W max

  • Isolation Voltage (User to System): 2550 VDC, 1 s

  • Terminal Connection: TC-TBCH, 36-position block

  • Shipping Weight: 1.5 kg

  • Operating Temperature: Standard industrial range

  • Construction: Rugged, low-power design for long-term reliability

Features

  • High Accuracy: 16-bit resolution ensures precise analog measurement

  • Multi-Range Input: Supports both voltage and current signals

  • RFI Resistant: Maintains <2% error across wide frequency spectrum

  • Robust Isolation: Protects system and user circuits with 2550 VDC tested isolation

  • Compact Layout: 16-channel design optimized for TC-TBCH terminal blocks

  • Durable Build: Low power dissipation and industrial-grade materials for consistent performance

Applications

  • Process control requiring multiple analog inputs

  • Monitoring of voltage and current sensors

  • Integration with Experion PKS and TDC 3000 systems

FAQ

Q: What is the primary function of the TC-IAH161 module?
A: It converts analog voltage and current signals into digital values for control and monitoring systems.

Q: How many channels are supported?
A: 16 channels, each with high-precision 16-bit resolution.

Q: How does it handle electrical interference?
A: RFI immunity ensures less than 2% measurement error at 10 V/m over 27–1000 MHz.

Q: Which industries benefit from this module?
A: Suitable for manufacturing, power generation, chemical processing, and water treatment facilities.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Modern factory automation relies heavily on robust Industrial Ethernet communications. Control system engineers deploy managed Ethernet switches to connect programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and field I/O devices. Selecting between Layer-2 and Layer-3 switching architecture directly impacts network throughput, routing capabilities, and overall cybersecurity defense in operational technology (OT) networks.

Read more
Understanding OpenTelemetry in Industrial Automation: Architecture, Observability, and Operational Benefits

Understanding OpenTelemetry in Industrial Automation: Architecture, Observability, and Operational Benefits

Modern industrial control systems (PLCs, DCS, edge nodes) are rapidly adopting cloud-native architectures, generating vast operational data. OpenTelemetry offers an open-source framework that unifies metrics, logs, and execution traces, enabling standardized observability across industrial automation and IT systems.

Read more
Mastering Functional Safety Terminology in Industrial Automation

Mastering Functional Safety Terminology in Industrial Automation

In modern process control and factory automation, managing operational risk is a top engineering priority. High-speed machinery, high-pressure vessels, and continuous processes present constant hazards to personnel and equipment. Modern plant operations rely heavily on functional safety strategies to mitigate these risks. This guide breaks down the essential functional safety terminology that every control systems engineer should master.

Read more