PRODUCT SKU : 140ACI04000

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 140ACI04000 is a high-precision 16-channel analog input module designed for the Modicon Quantum automation platform. It provides accurate current measurement with excellent linearity and stability, supporting differential inputs for robust signal acquisition.

Technical Specifications

  • Model + Part Number: 140ACI04000

  • Manufacturer: Schneider Electric

  • Product Line: Modicon Quantum

  • Product Type: Analog Input Module

  • Analog Input Channels: 16

  • Input Type: Differential

  • Input Range: 0…25 mA, 0…20 mA, 4…20 mA

  • Input Resolution:

    • 0…16000 counts for 4…20 mA

    • 0…20000 counts for 0…20 mA

    • 0…25000 counts for 0…25 mA

    • 0…4095 counts for 4…20 mA (alternative)

  • Absolute Maximum Input: 30 mA

  • Input Impedance: 250 Ω

  • Absolute Accuracy: ±0.125% of full scale

  • Linearity Error:

    • ±12 μA for 4…20 mA

    • ±6 μA for 0…20 mA

    • ±6 μA for 0…25 mA

  • Temperature Drift: ±0.0025% of full scale/°C

  • Common Mode Rejection: >90 dB at 60 Hz

  • Isolation Between Channels and Bus: 1780 V AC for 60 s

  • Update Time: 15 ms for 2- and 4-wire inputs

  • Fault Detection: Broken wire detection for 4…20 mA circuits

  • Local Signalling:

    • 1 green LED for bus activity

    • 1 red LED for external fault

    • 16 green LEDs for channel active

    • 16 red LEDs for channel fault

  • Bus Current Requirement: 360 mA

  • Power Dissipation: 5 W

  • Module Format: Standard

  • Net Weight: 0.66 lb (0.3 kg)

Applications
Suitable for monitoring multiple analog current signals in process control systems, the 140ACI04000 ensures accurate data acquisition for Modicon Quantum controllers in manufacturing and process industries.

FAQ
Q: What is the maximum input current supported?
A: The module can handle up to 30 mA absolute maximum input.
Q: How is fault detection implemented?
A: It detects broken wires on 4…20 mA input circuits.
Q: What update rate does it provide for input channels?
A: The update time is 15 ms for 2-wire and 4-wire configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding the Main Types of Industrial Control Systems in Modern Automation

Understanding the Main Types of Industrial Control Systems in Modern Automation

Industrial control systems (ICS) form the foundation of modern automation, ensuring safe and efficient operations. The main types—DCS, RTU, and PLC—manage processes, equipment, and communication across industries, each optimized for specific scales, response times, and operational environments.

Read more
Understanding PLC Redundancy in Industrial Automation: Ensuring Reliability and Continuous Operation

Understanding PLC Redundancy in Industrial Automation: Ensuring Reliability and Continuous Operation

In industrial automation, PLC redundancy ensures uninterrupted control and system reliability. By using backup processors and communication paths, these systems instantly take over during failures, minimizing downtime and protecting critical operations, safety, and productivity in modern industrial environments.

Read more
Allen-Bradley AADvance Controllers: Scalable Safety and Performance for Modern Industrial Automation

Allen-Bradley AADvance Controllers: Scalable Safety and Performance for Modern Industrial Automation

Allen-Bradley AADvance Controllers provide advanced, modular control for complex industrial automation systems. Designed for both standard and safety-critical operations, they deliver powerful processing, flexible I/O, and scalable performance for next-generation process and factory automation.

Read more