Skip to content

What are you looking for?


You may also like

ICS Triplex T8193 Trusted Shield Module for TMR SystemsICS Triplex T8193 Trusted Shield Module for TMR SystemsICS Triplex T8193 Trusted Shield Module for TMR Systems
ICS Triplex T8193 Trusted Shield Module for TMR Systems
ICS Triplex T8193 Trusted Shield Module for TMR Systems
ICS Triplex T8193 Trusted Shield Module for TMR Systems

ICS Triplex T8193 Trusted Shield Module for TMR Systems


Only 10 left - Selling fast

PRODUCT SKU : T8193

PRODUCT TYPE : Trusted Shield Module

PRODUCT VENDOR : ICS Triplex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ICS Triplex T8193 is a specialized shielding and grounding module designed for the Trusted Triple Modular Redundancy (TMR) system. It provides a dedicated interface for managing cable shields and signal grounding, effectively reducing electromagnetic interference (EMC) and ensuring high-integrity signal transmission for safety-critical I/O circuits.

Specifications

  • Manufacturer: Rockwell Automation (ICS Triplex).

  • Country of Origin: United Kingdom.

  • Model Number: T8193.

  • Interface Type: Passive grounding and shielding interface.

  • Compatibility: Trusted TMR Controller and Expansion Chassis.

  • Physical Weight: Approximately 0.6 kg (1.3 lbs).

  • Dimensions: 16cm x 16cm x 12cm

  • Mounting: Standard Trusted Chassis I/O slot.

  • Operating Temperature: -5°C to +60°C (23°F to 140°F).

Features

  • EMC Interference Mitigation: Provides a low-impedance path to earth for cable shields, protecting sensitive analog and digital signals from high-frequency noise.

  • Common Grounding Point: Centralizes signal shield terminations to prevent ground loops that could lead to signal distortion or hardware damage.

  • Passive Reliability: Constructed with robust mechanical components requiring no external power, ensuring consistent performance in safety environments.

  • System Integration: Perfectly fits the standard Trusted backplane footprint, allowing for organized cable management within the controller rack.

  • High-Density Termination: Supports multiple shield connections per module, simplifying the wiring of complex, high-channel-count safety installations.

  • Protective Barrier: Acts as an electrical guard between the external field wiring and the internal system electronics to enhance overall system robustness.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more