Skip to content

What are you looking for?


You may also like

ICS Triplex DO-C5S3 Redundant Digital Output ModulesICS Triplex DO-C5S3 Redundant Digital Output ModulesICS Triplex DO-C5S3 Redundant Digital Output Modules
ICS Triplex DO-C5S3 Redundant Digital Output Modules
ICS Triplex DO-C5S3 Redundant Digital Output Modules
ICS Triplex DO-C5S3 Redundant Digital Output Modules

ICS Triplex DO-C5S3 Redundant Digital Output Modules


Only 10 left - Selling fast

PRODUCT SKU : DO-C5S3

PRODUCT TYPE : Redundant Digital Output Modules

PRODUCT VENDOR : ICS Triplex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ICS Triplex DO-C5S3, also cataloged as the DO-C5S3 Redundant Digital Output Module, operates as a dedicated hardware component for high-integrity discrete control execution within ICS Triplex Trusted safety instrumented system platforms. The unit conditions and switches physical output command signals to external final elements, including actuators, interlock relays, and alarm indicators.

Hardware Specifications

Parameter Specification
Model DO-C5S3
Brand ICS Triplex
Origin United Kingdom
Weight 1.1 kg (2.43 lbs)
Dimensions 32 mm x 265 mm x 360 mm
Operating Temp 0 to +60 deg C (+32 to +140 deg F)
Power Consumption System Backplane Powered (Load Dependent)
Product Type Redundant Digital Output Module
Circuit Architecture Triple Modular Redundancy (TMR)
System Compatibility ICS Triplex Trusted System

Triple Modular Redundancy and Galvanic Isolation

The ICS Triplex DO-C5S3 digital output module is engineered to comply with SIL3 certification standards across critical safety instrumented systems. Built upon a triple modular redundancy (TMR) 2oo3 architecture, the module executes voting logic across three isolated processing paths to drive physical output channels. Internal galvanic isolation decouples field-side load circuits from internal backplane logic, preventing transient voltage spikes and ground potential shifts from affecting controller performance while enforcing fail-safe state execution during detected channel faults.

Frequently Asked Questions

Q: Does the DO-C5S3 module support online hot-swapping during active system operation?

A: Yes, in a redundant chassis slot configuration, the DO-C5S3 can be replaced online without disrupting active control signals to external field devices.

Q: How does the internal 2oo3 TMR voting architecture handle a single output channel failure?

A: If one processing channel experiences a failure, the 2oo3 voting circuit overrides the faulted channel, maintaining output state integrity and allowing continuous system execution.

Field Installation Guidelines

  1. Ensure chassis power and backplane interlocks are verified prior to inserting the DO-C5S3 module into its designated rack slot.
  2. Align the module top and bottom circuit board edge guides with the chassis card cage slots, pushing firmly until the backplane connectors fully seat.
  3. Fasten the top and bottom captive retention screws to ensure continuous mechanical ground continuity and prevent vibration-induced unseating.
  4. Verify that field output wiring to actuators or relays is routed through approved field termination assemblies (FTAs) with appropriate fusing

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more
ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

Selecting the right control strategy impacts process stability, efficiency, and equipment lifespan. This technical comparison evaluates binary ON-OFF and continuous PID control algorithms, analyzing their mathematical behavior, operational differences, and practical selection criteria for factory automation.
Read more