Product Details

The Emerson EPRO CON010+PR6426/010-140, also cataloged as the CON010+PR6426/010-140 Eddy Current Sensor System, operates as a dedicated hardware component for non-contact shaft displacement measurement within turbomachinery monitoring systems.

Hardware Specifications

Parameter Specification
Model CON010+PR6426/010-140
Brand Emerson EPRO
Base Model CON010+PR6426/010-140
Origin Germany
Weight Approx 1.4 kg
Dimensions 32 mm sensor head diameter
Operating Temp -35 to +180 deg C (short excursions up to +200 deg C)
Power Consumption Powered via converter loop connection
System Components PR6426 probe, extension cable, CON010 converter
Measurement Range +/-4.0 mm (+/-0.157 in)
Linear Range 0 to 20 mm
Sensitivity 2 V/mm (50.8 mV/mil), +/-1.5% max
Accuracy +/-0.1 mm
Repeatability +/-0.05 mm
Target Material Ferromagnetic steel (42CrMo4 / AISI 4140)
Target Limits Min shaft diameter >=200 mm, max surface speed 2500 m/s
Connector Type LEMO industrial-grade connector
Shock & Vibration 5 g at 60 Hz, 25 deg C

Eddy-Current Probe Scaling and Gap Voltage Validation

The CON010+PR6426/010-140 system relies on precise eddy-current probe scaling to convert high-frequency magnetic field alterations into standard analog voltage outputs. During physical setup, gap voltage validation targets nominal DC offset voltages to verify the uncalibrated mechanical clearance between the 32 mm probe tip and target shaft material. Proper zero-gap setup suppresses signal cross-talk and preserves a linear sensitivity of 2 V/mm across the entire +/-4.0 mm dynamic measurement range.

Frequently Asked Questions

Q: What components constitute the complete CON010+PR6426/010-140 system measurement chain?

A: The system consists of three matched physical components: the PR6426/010-140 non-contact probe head, an extension cable with LEMO industrial connectors, and the CON010 signal converter module.

Q: What are the thermal limits for the probe head during operation near hot turbine casings?

A: The probe head operates continuously within a temperature window of -35 to +180 deg C, with short-term thermal excursion tolerance up to +200 deg C.

Q: What target shaft parameters are required to maintain linear signal calibration?

A: Calibration requires a ferromagnetic steel target material (42CrMo4 / AISI 4140) with a minimum shaft diameter of 200 mm or greater.

Field Installation Guidelines

  1. Mount the 32 mm probe head into the machine casing bracket using calibrated threaded fixtures.
  2. Measure unpowered static physical gap and adjust probe depth until the signal output matches the required DC gap voltage baseline.
  3. Connect the probe lead to the CON010 converter using the LEMO extension cable, ensuring connectors are fully seated and protected from oil exposure.
  4. Route signal cables away from high-voltage motor leads and variable frequency drive wiring to prevent electromagnetic interference.
  5. Secure field wiring shields to a single-point system ground block at the monitoring rack end.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Selecting the proper control architecture remains a pivotal decision when designing industrial automation systems. Automation engineers must evaluate whether a batch or continuous process model best fits their production requirements. This fundamental choice influences PLC and DCS programming, hardware redundancy, sensor selection, and overall factory automation layouts.

Read more
Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Industrial automation systems rely on pristine analog signal transmission across complex control loops. Instrument technicians and system integrators frequently deploy signal isolators to maintain signal integrity between field sensors and control platforms. Eliminating electrical noise, ground loops, and high-voltage transients protects delicate PLC, DCS, and SCADA input channels from permanent damage.

Read more
Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Modern factory automation relies on distinct control architectures to manage complex process environments efficiently. Control engineers often evaluate PLC, DCS, RTU, SCADA, and PAC platforms when designing industrial infrastructure. Understanding the functional boundaries of each technology ensures optimal system performance, high availability, and long-term cost efficiency.

Read more