Skip to content

What are you looking for?


You may also like

DIO216 | Digital Input/Output Module | BachmannDIO216 | Digital Input/Output Module | BachmannDIO216 | Digital Input/Output Module | Bachmann
DIO216 | Digital Input/Output Module | Bachmann
DIO216 | Digital Input/Output Module | Bachmann
DIO216 | Digital Input/Output Module | Bachmann

DIO216 | Digital Input/Output Module | Bachmann


Only 10 left - Selling fast

PRODUCT SKU : DIO216

PRODUCT TYPE : Digital Input/Output Module

PRODUCT VENDOR : Bachmann


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Bachmann DIO216 is a multifunctional digital input/output module designed for industrial automation tasks. Combining both inputs and outputs, it provides versatile control and monitoring capabilities for a wide range of digital devices in automation systems. Its robust design and broad operating range ensure reliable performance in demanding environments.

Specifications

Inputs

  • Quantity: Up to 16 digital inputs

  • High-Level Input Voltage: 15–34 VDC

  • Low-Level Input Voltage: 0–5 VDC

  • Normal Input Delay: 600 µs

  • Internal Resistance: 6.8 kΩ

  • Status Indicator: Green LED

  • Interrupt Inputs: 1

Outputs

  • Quantity: Up to 16 digital outputs

  • Output Voltage Range: 18–34 VDC

  • Maximum Output Current per Channel: 1 A

  • Maximum Total Current: 12 A

  • Status Indicator: Green LED

  • Maximum Switching Frequency (Ohmic Load): 1 kHz

External Power Supply

  • Reverse Polarity Protection: Yes

  • Galvanic Isolation from System: 500 V

Certifications and Approvals

  • General: CE, cULus, CCC

  • Marine: DNV GL, LR, ABS, BV

Environmental Conditions

  • Operating Temperature: -30 to +60 °C

  • Operating Humidity: 5–95% without condensation

  • Storage Temperature: -40 to +85 °C

  • Storage Humidity: 5–95% with condensation

  • Pollution Degree: 2 (IEC 60664-1, without condensation)

Physical Characteristics

  • Dimensions: 5.4 cm x 11.8 cm x 7.0 cm (2.1" x 4.6" x 2.8")

  • Weight: 0.3 kg

Features

  • Combined I/O Module: Integrates both digital inputs and outputs for versatile control

  • High Switching Frequency: Supports up to 1 kHz for rapid signal processing

  • Galvanic Isolation: Ensures safe separation between module and system power

  • Robust LED Indicators: Provide clear real-time status for inputs, outputs, and module operation

  • Wide Voltage Range: Suitable for diverse industrial power systems

  • Industrial-Grade Design: Operates reliably under extreme temperatures and high humidity

  • Marine-Ready: Certified for use in marine applications with DNV GL, LR, ABS, and BV approvals

Applications

The DIO216 is suitable for factory automation, process control, and marine automation systems. It can be used for monitoring sensors, controlling actuators, and handling complex digital signaling tasks in high-reliability environments.

FAQ

Q: How many inputs and outputs does this module support?
A: The DIO216 supports up to 16 digital inputs and 16 digital outputs simultaneously.

Q: Can it handle high switching speeds?
A: Yes, the module supports up to 1 kHz switching frequency on resistive loads.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more