PRODUCT SKU : CON041+PR6423/004-031-CN

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-frequency signal conditioning in vibration monitoring networks, the Emerson Epro CON041+PR6423/004-031-CN (PR6423/004-031-CN) Eddy Current Sensor System provides direct physical execution of raw sensor signal linearization for industrial displacement acquisition.

Hardware Specifications

Parameter Specification
Model CON041+PR6423/004-031-CN
Brand Emerson Epro
Dimensions 65 mm Case Thread
Operating Temp -30 deg C to 100 deg C (Converter)
Power Consumption -23 VDC to -32 VDC (or -21 VDC to -32 VDC)

Mechanical Monitoring and TSI Integration

The system employs eddy-current induction to measure the clearance between the probe tip and a metallic rotor. Successful rotor dynamics analysis requires accurate eddy-current probe scaling, ensuring the transducer voltage output remains linearly proportional to shaft displacement. During initial setup, users must perform gap voltage validation, targeting a -10 VDC center point to ensure the signal remains within the linear dynamic range of the probe. To maintain high-fidelity waveform capture, the system utilizes effective cross-talk suppression by ensuring that the high-frequency coaxial cables are routed independently from electromagnetic noise sources, preventing interference with the detection of shaft eccentricity and orbital vibration patterns.

Frequently Asked Questions

Q: Is the system compatible with non-ferromagnetic shaft materials?

A: No. The system is optimized for 42CrMo4 (AISI/SAE 4140) ferromagnetic steel targets. Utilizing non-ferromagnetic materials will lead to a non-linear signal response and reduced measurement sensitivity.

Q: Are there specific installation requirements for the open-ended coaxial cable?

A: The cable ends must be terminated into high-quality shielded terminal blocks or connectors to maintain impedance. Ensure shielding is maintained up to the converter input to prevent pick-up of common-mode noise.

Field Installation Guidelines

  1. Probe Mounting: Secure the sensor in a rigid, vibration-isolated bracket to ensure measured displacement is relative to the shaft and not the machine casing.
  2. Gap Adjustment: Utilize a calibrated feeler gauge to establish the nominal air gap. Verify that the sensor tip is positioned to accommodate the full range of shaft thermal expansion and dynamic movement without mechanical contact.
  3. Grounding: Terminate cable shields at a dedicated instrument ground bus. Ensure the CON041 converter housing is properly grounded to mitigate common-mode noise and ground loops.
  4. Environment: Protect the converter from direct fluid exposure. Ensure all connections are tightened to prevent ingress of conductive dust or moisture, which could cause drift in the signal reference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more