Product Details

Product Overview

The Allen Bradley 1763-L16AWA serves as a versatile, compact controller within the MicroLogix 1100 family. This PLC excels in small-scale industrial applications requiring robust AC input processing and localized control. We supply this unit as 100% Brand New and Original, featuring an integrated LCD screen for real-time diagnostics and a built-in Ethernet/IP port for seamless network integration. It provides a cost-effective solution for monitoring 120V AC signals directly without interposing relays.

Technical Specifications

The 1763-L16AWA handles high-voltage AC signals with precision using the following electrical parameters:

Feature Specification
On-State Voltage Range 79V AC to 132V AC
Off-State Voltage Range 0V AC to 20V AC
Operating Frequency 47 Hz to 63 Hz
Nominal Input Current 12 mA @ 120V AC
Maximum Input Current 16.0 mA @ 132V AC
Max Off-State Leakage 2.5 mA
Nominal Impedance 10 kΩ @ 60 Hz; 12 kΩ @ 50 Hz
Max Inrush Current 250 mA @ 120V AC
Input Type 120V AC Digital Inputs

Engineering Advantages

  • Direct 120V AC Interfacing: The controller accepts standard 120V AC inputs directly. This eliminates the need for 24V DC power supplies and interposing relays when interfacing with standard industrial pushbuttons and limit switches, significantly reducing panel complexity and wiring costs.

  • Robust Signal Filtering: Built-in impedance matching (10 kΩ at 60 Hz) filters out electrical noise common in high-voltage AC circuits. This ensures the PLC distinguishes between true logic signals and induced "ghost" voltages from parallel power lines.

  • Integrated Visual Diagnostics: The onboard LCD allows maintenance personnel to monitor I/O status and modify controller bits without connecting a PC. This feature accelerates onsite troubleshooting and reduces downtime during machine commissioning.

  • High Inrush Tolerance: The input circuitry manages inrush currents up to 250 mA. This protection prevents hardware damage when triggering inputs from capacitive sources or long cable runs that exhibit high initial surge characteristics.

  • Deterministic Input Detection: A narrow off-state window (below 20V AC) ensures the PLC maintains a deterministic state. This prevent accidental triggering due to leakage current from solid-state sensors or proximity switches.

FAQs

  • What is the significance of the "AWA" suffix in 1763-L16AWA?

    The "AWA" designation indicates that the unit utilizes an AC power supply, 120V AC inputs, and Relay outputs. This configuration suits traditional industrial environments where AC control power is the primary standard.

  • Can the 1763-L16AWA operate on both 50 Hz and 60 Hz grids?

    Yes. The controller supports an operating frequency range of 47 to 63 Hz. It automatically adjusts its nominal impedance to provide stable signal detection regardless of the local power grid standard.

  • How do I protect the inputs from excessive leakage current?

    Ensure that any connected solid-state sensors do not exceed a 2.5 mA off-state leakage current. If a sensor exceeds this limit, we recommend installing a bleeder resistor to shunt the excess current and maintain reliable "Off" states.

  • Is this a genuine, factory-sealed unit?

    Absolutely. We guarantee this 1763-L16AWA is 100% Brand New original hardware. It arrives in the original Allen Bradley factory packaging with all security seals and technical documentation intact.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more