Skip to content

What are you looking for?


You may also like

ABB CI840 3BSE022457R1 S800 I/O Redundant PROFIBUS DP-V1 InterfaceABB CI840 3BSE022457R1 S800 I/O Redundant PROFIBUS DP-V1 InterfaceABB CI840 3BSE022457R1 S800 I/O Redundant PROFIBUS DP-V1 Interface
ABB CI840 3BSE022457R1 S800 I/O Redundant PROFIBUS DP-V1 Interface
ABB CI840 3BSE022457R1 S800 I/O Redundant PROFIBUS DP-V1 Interface
ABB CI840 3BSE022457R1 S800 I/O Redundant PROFIBUS DP-V1 Interface

ABB CI840 3BSE022457R1 S800 I/O Redundant PROFIBUS DP-V1 Interface


Only 10 left - Selling fast

PRODUCT SKU : CI840 3BSE022457R1

PRODUCT TYPE : Communication Interface

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The CI840 manages the operations of a complete S800 I/O cluster, supporting up to 12 modules per station. It facilitates high-speed cyclical data exchange and acyclic communication for advanced device diagnostics and parameterization via the PROFIBUS DP-V1 standard. When used in a redundant pair with a dedicated Module Termination Unit (MTU), the CI840 provides a fault-tolerant communication solution that eliminates single points of failure. This module is widely utilized in the oil and gas, chemical, and power industries where continuous process monitoring is non-negotiable.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Sweden

  • Model Number: CI840 (3BSE022457R1)

  • Protocol: PROFIBUS DP-V1

  • Transmission Rate: Up to 12 Mbit/s (Auto-baud detection)

  • Capacity: Supports up to 12 S800 I/O modules per FCI

  • Redundancy: Supports 1:1 redundant FCI pairs

  • Input Voltage: 24 VDC nominal

  • Operating Current: 160 mA typical

  • Addressing: Configuration via rotary switches (1–125)

Features

  • High-Availability Redundancy: Provides seamless failover capabilities when configured in pairs, ensuring the control system maintains contact with field I/O during hardware maintenance.

  • DP-V1 Enhanced Diagnostics: Supports acyclic data services, allowing for sophisticated asset management and deeper diagnostic insights into smart field devices.

  • Deterministic Performance: Maintains low-latency communication at speeds up to 12 Mbps, suitable for high-speed process control loops.

  • Automated Module Configuration: Automatically initializes and loads parameters to all connected I/O units upon startup or module replacement.

  • Flexible Installation: Easily integrates into standard DIN-rail setups and is compatible with a wide range of single and redundant MTUs.

  • Industrial Hardening: Features high-level galvanic isolation and EMI protection to ensure stable operation in electrically noisy plant environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more