Skip to content

What are you looking for?


You may also like

CI522-MODTCP 1SAP222200R0001 ABB S500 Interface ModuleCI522-MODTCP 1SAP222200R0001 ABB S500 Interface ModuleCI522-MODTCP 1SAP222200R0001 ABB S500 Interface Module
CI522-MODTCP 1SAP222200R0001 ABB S500 Interface Module
CI522-MODTCP 1SAP222200R0001 ABB S500 Interface Module
CI522-MODTCP 1SAP222200R0001 ABB S500 Interface Module

CI522-MODTCP 1SAP222200R0001 ABB S500 Interface Module


Only 10 left - Selling fast

PRODUCT SKU : CI522-MODTCP 1SAP222200R0001

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB CI522-MODTCP 1SAP222200R0001, also cataloged as the CI522-MODTCP Interface Module, serves as the primary CI522-MODTCP Interface Module utilized to execute high-speed data exchange across Modbus TCP networks for S500 architectures.

Hardware Specifications

Parameter Specification
Model CI522-MODTCP 1SAP222200R0001
Brand ABB
Origin Germany
Weight 0.133 kg
Dimensions 62 mm D x 76 mm H x 67.5 mm W
Operating Temp Standard Industrial Limits (Refer to Manual)
Power Consumption Supply Voltage: 20.4 - 28.8 VDC
Communication Protocol Modbus TCP Server
Digital Inputs 8 DI (24 VDC, 5 mA)
Digital Outputs 8 DO (24 VDC, 0.5 A)
Configurable Channels 8 DI/DO (24 VDC, 0.5 A)
Expansion Capacity Up to 10 additional I/O modules
Ingress Protection IP20

Deterministic Network Profiles and I/O Density Scaling

The module handles distributed field data via embedded Ethernet interfaces running the standard Modbus TCP protocol layer. Real-time deterministic communication updates input and output memory registers synchronously with local logic execution cycles. To optimize terminal setups, the architecture accommodates local I/O density scaling up to 10 additional expansion blocks, distributing both physical signal routing and bus current distribution directly through the internal platform connections.

Frequently Asked Questions

Q: Does the CI522-MODTCP module support hot-swap capabilities for its expansion I/O blocks?

A: No, standard S500 backplane logic does not permit the removal or insertion of expansion I/O modules while the 24 VDC primary power is applied to the CI522-MODTCP. Doing so induces an immediate internal system bus fault and cuts off network communication.

Q: How do the 8 configurable DI/DO channels behave upon a loss of Modbus TCP communication?

A: When a communication timeout is registered by the network logic, channels assigned as digital outputs drop to their fail-safe state or hold last state depending on the software parameter table flashed to the module prior to commissioning.

Field Installation Guidelines

  • DIN-rail Mounting Stability: Snap the module firmly onto standard 35 mm DIN rails. Ensure the rear grounding spring makes positive structural contact with an unpainted, conductive rail surface to maintain shielding effectiveness.
  • Wiring Configurations: Route all 24 VDC power and I/O signal conductors through terminal blocks separate from high-voltage AC cables. Use wires matching the 0.5 A rating for the DO circuits to prevent terminal over-heating.
  • Network Segment Isolation: Shielded twisted-pair (STP) Cat 5e or Cat 6 cabling must be utilized for the Modbus TCP connections. Ground the cable shielding at the switch end to minimize electromagnetic noise coupling on the differential signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more