Product Overview

The Yokogawa VI701 acts as the high-speed communication gateway for CENTUM VP control systems, facilitating Vnet/IP connectivity via a standard PCI bus architecture. This interface card enables real-time, large-capacity data exchange between Human Interface Stations (HIS), Engineering Stations (ENG), and the control network. By utilizing Gigabit Ethernet technology, the VI701 ensures deterministic communication and low-latency synchronization across the Distributed Control System (DCS).

Technical Specifications

The VI701 integrates robust networking capabilities with standard industrial computer hardware:

Feature Specification
Communication Speed 1000 Mbps Full Duplex
Transmission Standard 1000Base-T compliant
Connection Port RJ45 Connector
Cable Requirement CAT5e (Enhanced Category 5) UTP
Max. Transmission Distance 100 m (to Layer 2 Switch)
PCI Specification Revision 3.0
Bus Width/Frequency 32-bit / 33 MHz
Power Consumption Max. 2.5 A
Dimensions 106.68 mm x 167.64 mm
Weight 0.2 kg
Condition 100% Brand New and Original

Engineering Advantages

  • Gigabit Throughput: The VI701 delivers 1000 Mbps full-duplex throughput. This high bandwidth eliminates data bottlenecks in complex plants with thousands of I/O points, ensuring the operator console updates instantly during process upsets.

  • On-Board Diagnostics: Three dedicated LED indicators (RDY, RCV, SND) provide immediate hardware feedback. The RDY lamp illuminates only after the card passes internal self-diagnostics, while the RCV and SND lamps verify active traffic on the control bus, simplifying field troubleshooting.

  • Standardized Infrastructure: The card utilizes standard CAT5e cabling and RJ45 connectors. This choice reduces installation costs by allowing the use of conventional industrial Ethernet infrastructure while maintaining high-fidelity signal transmission up to 100 meters.

  • Legacy PCI Support: The VI701 complies with PCI Bus Specification 3.0. This allows engineers to sustain or upgrade existing industrial PC stations without requiring a total hardware overhaul, providing a cost-effective path for system expansion.

FAQs

  • Is this Yokogawa VI701 card brand new or a refurbished pull?

    We offer this VI701 exclusively as 100% Brand New and Original equipment. Each card arrives in its anti-static packaging within the original Yokogawa factory box, ensuring peak performance and full manufacturer-rated lifespan.

  • What do the different LED lamps indicate during operation?

    The RDY lamp confirms the card's internal health. The SND lamp flickers when the HIS/ENG sends data to the control network, and the RCV lamp activates upon detecting incoming signals from the Vnet/IP bus. If the RDY lamp remains off, the card has failed its power-on self-test.

  • Does the VI701 require a specific type of Ethernet cable?

    Yes. You must use CAT5e Enhanced Category 5 UTP cable or better to maintain 1000Base-T compliance. Using lower-rated cables will result in packet loss or reduced communication speeds, compromising DCS stability.

  • What is the maximum distance allowed for a direct connection?

    The VI701 supports a maximum cable length of 100 meters between the card's RJ45 port and the Layer 2 switch. For distances exceeding 100 meters, you must implement fiber optic converters or additional industrial switches.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more