Skip to content

What are you looking for?


You may also like

Yokogawa F3LE11-1T FA-M3 Ethernet Communication Interface ModuleYokogawa F3LE11-1T FA-M3 Ethernet Communication Interface ModuleYokogawa F3LE11-1T FA-M3 Ethernet Communication Interface Module
Yokogawa F3LE11-1T FA-M3 Ethernet Communication Interface Module
Yokogawa F3LE11-1T FA-M3 Ethernet Communication Interface Module
Yokogawa F3LE11-1T FA-M3 Ethernet Communication Interface Module

Yokogawa F3LE11-1T FA-M3 Ethernet Communication Interface Module


Only 10 left - Selling fast

PRODUCT SKU : F3LE11-1T

PRODUCT TYPE : Communication Interface Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa F3LE11-1T serves as the primary gateway for connecting FA-M3 series PLCs to high-speed Ethernet networks. This module facilitates seamless data exchange between the controller and supervisory systems, supporting both 10BASE-T and 100BASE-TX standards. We supply this unit as 100% Brand New and Original, ensuring your automation architecture utilizes the latest factory-standard hardware for remote monitoring and industrial data logging.

Technical Specifications

Feature Details
Network Standards IEEE 802.3 Compliant
Transmission Speed 10 Mbps (10BASE-T) / 100 Mbps (100BASE-TX)
Protocol Stack TCP/IP, SMTP, POP3
Max Segment Length 100 meters
Access Control CSMA/CD
Current Consumption 330 mA maximum
Dimensions 28.9 (W) × 100 (H) × 83.2 (D) mm
Weight 100 g

Engineering Advantages

  • Enhanced Diagnostic Connectivity: The F3LE11-1T integrates SMTP and POP3 protocols, allowing the PLC to send automated email alerts regarding system status or alarm triggers. This functionality eliminates the need for constant manual oversight and speeds up response times for maintenance teams.

  • Dual-Speed Auto-Negotiation: The module supports 10/100 Mbps speeds, allowing it to interface with both legacy industrial hubs and modern high-speed switches. This versatility ensures stable performance regardless of the existing network infrastructure.

  • High-Density Rack Efficiency: With a width of only 28.9 mm and a weight of 100g, this module maintains a low physical footprint. It slides easily into standard FA-M3 PLC racks, preserving valuable slot space for additional I/O or motion control modules.

  • Stable Baseband Transmission: The hardware utilizes baseband transmission and CSMA/CD access control to minimize data collisions. This ensures deterministic communication paths required for real-time remote monitoring and synchronized data logging systems.

FAQs

  • Does this module support fiber optic connections? No, the F3LE11-1T utilizes standard RJ-45 connectors for twisted-pair copper cabling. To transition to fiber, you must use an external media converter or an alternative Yokogawa fiber-specific interface module.

  • How do I configure the email notification feature? You configure the SMTP server settings and recipient addresses within the FA-M3 programming environment. The module then triggers emails based on specific ladder logic conditions or register values defined by the user.

  • Is the F3LE11-1T compatible with all FA-M3 CPU types? The F3LE11-1T works with most standard FA-M3 CPU modules. However, always verify that your specific CPU firmware version supports Ethernet communication functions to ensure full protocol transparency.

  • What is the maximum number of segments allowed in a cascade setup? The module supports up to 2 segments or up to 4 segments depending on your specific network topology and the type of switching equipment used. For maximum stability over 100 meters, we recommend using active industrial switches.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more