Skip to content

What are you looking for?


You may also like

Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal BlockYokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal BlockYokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block
Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block
Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block
Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block

Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block


Only 10 left - Selling fast

PRODUCT SKU : ATR8D-00

PRODUCT TYPE : Redundant Terminal Block

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The ATR8S-00 (Part No. ATR8D-00) is a specialized signal conditioning and termination interface designed for Yokogawa’s CENTUM VP and CS 3000 Field Control Stations. Engineered specifically for high-availability temperature monitoring, this unit facilitates the integration of RTD and Thermocouple sensors into the AAR181 and similar I/O modules.

The primary engineering advantage of the ATR8D-00 lies in its redundant branching capability. It allows a single set of field sensors to be cross-connected to two separate I/O modules, ensuring that a single module failure does not result in the loss of critical process data. The M3.5 pressure clamp terminals are designed to maintain a gas-tight seal, which is vital for preventing oxidation of low-millivolt signals in corrosive chemical environments.

Technical Specifications

  • Manufacturer: Yokogawa Electric Corporation

  • Model Identification: ATR8D-00

  • I/O Capacity: 8 Differential Channels

  • Redundancy Support: Dual-redundant module branching

  • Terminal Interface: M3.5 Pressure Clamp (Spring-loaded contact)

  • Dielectric Strength: 500 V AC (Terminals to Ground)

  • Insulation Resistance: 10 MΩ minimum at 500 V DC

  • Sensor Compatibility: Pt100, Pt50, JPt100 (RTD); Type K, J, T, E, B, R, S, N (TC)

  • Cold Junction Compensation: Integrated reference sensors for Thermocouple precision

  • Operating Ambient: 0°C to 60°C (32°F to 140°F)

  • Relative Humidity: 5% to 95% RH (Non-condensing)

  • Weight: 0.8 kg (1.76 lbs)

  • Origin: Made in Japan

Operational Implementation

The ATR8D-00 (ATR8D-00) is typically deployed in mid-stream and downstream oil and gas applications where temperature excursions must be monitored with zero downtime. Unlike standard screw terminals that may loosen over time due to thermal cycling, the pressure clamp mechanism provides constant force, ensuring measurement stability for sensitive RTD resistance values.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more