Skip to content

What are you looking for?


You may also like

Yokogawa AAV141-S00 CENTUM VP Analog Input ModuleYokogawa AAV141-S00 CENTUM VP Analog Input ModuleYokogawa AAV141-S00 CENTUM VP Analog Input Module
Yokogawa AAV141-S00 CENTUM VP Analog Input Module
Yokogawa AAV141-S00 CENTUM VP Analog Input Module
Yokogawa AAV141-S00 CENTUM VP Analog Input Module

Yokogawa AAV141-S00 CENTUM VP Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAV141-S00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa AAV141-S00 functions as a high-density analog input module specifically engineered for the CENTUM VP distributed control system. This module processes 16 channels of 1 to 5 V DC signals, converting field sensor data into precise digital values for the control station. We supply this unit as 100% brand new and original, ensuring your automated processes maintain maximum uptime and signal integrity.

Part Number Breakdown: AAV141-S00

Yokogawa utilizes a specific suffix code system to define the hardware configuration of their I/O modules:

Code Specification Description
AAV141 Model Analog Input Module (1 to 5 V, 16-channel)
-S Suffix Standard Type
0 Suffix Basic Type
0 Suffix Always 0 (Fixed)

Technical Specifications

This module features a compact, lightweight design optimized for high-density cabinet installations:

  • Input Channels: 16-channel, non-isolated

  • Input Signal: 1 to 5 V DC

  • Allowable Input Voltage: -0.5 to 7.5 V DC

  • Input Resistance: 1 MΩ or greater (during power on)

  • Accuracy: ±0.1% of full scale

  • Data Refresh Cycle: 10 ms

  • Weight: 0.2 kg

  • Current Consumption: 450 mA maximum (5 V DC)

Engineering Advantages

The AAV141-S00 solves critical integration challenges in large-scale industrial environments:

  • High-Density Integration: By supporting 16 channels in a single 0.2 kg slot, this module reduces the physical footprint of your DCS cabinet, allowing for smaller enclosures or expanded capacity in existing spaces.

  • Seamless CENTUM VP Compatibility: This module integrates directly with the Yokogawa FIO (Field network I/O) bus. The system recognizes the hardware instantly, eliminating complex driver configurations and reducing commissioning time.

  • Superior Signal Precision: The high input resistance (1 MΩ) prevents signal loading errors. This ensures that the 1-5 V signals from your transmitters remain accurate, even across extended cable runs within the plant.

  • Thermal Efficiency: The low power consumption design minimizes heat dissipation within the I/O rack, extending the lifespan of adjacent electronic components in unventilated environments.

FAQs

  • Is this AAV141-S00 unit brand new?

    Yes. We supply only 100% brand new, original Yokogawa factory-sealed units. We do not deal in refurbished or used surplus.

  • Does this module require a specific terminal block?

    The AAV141-S00 connects to pressure clamp terminals or KS cable interface units. Ensure you verify your wiring methodology (direct terminal vs. marshalling) before installation.

  • Can I hot-swap this module during operation?

    Yes, the CENTUM VP architecture allows for the hot-swapping of I/O modules. However, you must follow standard safety protocols to ensure the 16 process loops remain stable during the transition.

  • What is the difference between AAV141 and AAV142?

    While both handle analog signals, the AAV141 targets 1-5 V inputs specifically. The AAV142 typically handles 4-20 mA current signals. Always match the module voltage/current specs to your field transmitter output.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more