Skip to content

What are you looking for?


You may also like

Yokogawa AAI835-S00 CENTUM VP 4-In/4-Out Isolated Analog I/O ModuleYokogawa AAI835-S00 CENTUM VP 4-In/4-Out Isolated Analog I/O ModuleYokogawa AAI835-S00 CENTUM VP 4-In/4-Out Isolated Analog I/O Module
Yokogawa AAI835-S00 CENTUM VP 4-In/4-Out Isolated Analog I/O Module
Yokogawa AAI835-S00 CENTUM VP 4-In/4-Out Isolated Analog I/O Module
Yokogawa AAI835-S00 CENTUM VP 4-In/4-Out Isolated Analog I/O Module

Yokogawa AAI835-S00 CENTUM VP 4-In/4-Out Isolated Analog I/O Module


Only 10 left - Selling fast

PRODUCT SKU : AAI835-S00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI835-S00 (Part Number: AAI835-S00) is a hybrid signal processing interface designed for Yokogawa’s CENTUM VP and CS 3000 distributed control systems. This module provides a dual-purpose architecture, hosting four dedicated 4 to 20 mA input channels and four dedicated 4 to 20 mA output channels within a single slot. This high-density design is specifically engineered for precision control loops where space optimization and galvanic isolation are paramount.

Every channel on the AAI835-S00 is electrically isolated from the system backplane and from other channels, effectively neutralizing ground loops and protecting the DCS from field-side electrical transients. The module is optimized for real-time responsiveness, featuring a rapid 10 ms update cycle. It supports various field connection methods including pressure clamp terminals and KS cable interfaces, ensuring it can be integrated into diverse cabinet designs with ease.

Detailed Technical Specifications

  • Primary Function: Combined Analog Input and Output Module

  • Input Configuration: 4 channels, 4 to 20 mA DC (Isolated)

  • Output Configuration: 4 channels, 4 to 20 mA DC (Isolated)

  • Data Refresh Frequency: 10 ms internal update period

  • Input Precision: ±16 μA

  • Output Precision: ±48 μA

  • Input Resistance (Active): 250 Ω nominal (varies 290–450 Ω based on current)

  • Output Load Capability: Supports 0 to 750 Ω resistance

  • Open-Circuit Detection: Output current monitoring below 0.65 mA

  • Field Power Output: >15.0 V at 20 mA; <29.3 V at 0 mA

  • Isolation Rating: 500 V AC dielectric strength for 1 minute

  • Thermal Stability: ±16 μA drift per 10°C variation

  • Current Consumption: 360 mA @ 5 V DC; 450 mA @ 24 V DC

  • Module Mounting: Compatible with ESB/ER bus node units

  • Digital Support: HART communication available (via firmware EB401 rev. 2+)

  • Physical Mass: 0.3 kg

Module Suffix and Option Code Breakdown

  • AAI835: Base model for 4-input/4-output isolated analog I/O

  • -S: Standard communication and performance specification

  • 0: Non-explosion protected variant for safe area installations

  • 0: Basic hardware functional type

Common Industrial Applications

  • Integrated Control Loops: Simultaneous sensing of flow rates and positioning of control valves in a single module.

  • Space-Constrained Cabinets: Reducing the physical footprint of I/O nests by combining input and output functions.

  • Isolated Signal Processing: Facilities with significant ground potential differences requiring channel-to-channel protection.

  • Critical Monitoring: High-speed 10ms data acquisition for fast-acting safety instrumented functions.

Frequently Asked Questions

Does this module support smart field devices?

Yes, the AAI835-S00 supports digital communication via the HART protocol when paired with appropriate firmware (EB401 rev. 2 or later). This allows for diagnostic pass-through from smart transmitters and positioners.

What happens if a field wire is disconnected?

The module features built-in open-circuit detection for the output side. If the loop current drops below 0.65 mA, the system will flag a diagnostic error to alert operators of the cable failure.

Can it power 2-wire transmitters?

The AAI835-S00 provides a built-in transmitter power supply capable of delivering at least 15V at full 20mA load, making it suitable for standard 2-wire loop-powered instruments.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more