PRODUCT SKU : AAI543-S50/K4A00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI143-S50/A4S00 from Yokogawa is a rack‑mounted analog input module designed for distributed control systems. It provides 16 isolated channels for acquiring 4–20 mA signals from field transmitters, ensuring accurate and stable data collection in process automation environments.

This model is part of the AAI143 series and is supplied with a pressure clamp terminal block (ATA4S-00) for secure wiring. The suffix codes define its configuration: “S” indicates the standard type, “5” specifies no explosion protection, “0” denotes the basic type, and “/A4S00” confirms the inclusion of the pressure clamp terminal block.

Technical Specifications

  • Model / Order Number: AAI143-S50/A4S00

  • Manufacturer: Yokogawa Electric Corporation

  • Type: Analog Input Module

  • Channels: 16 isolated analog inputs

  • Signal Range: 4–20 mA DC

  • Terminal Block: Pressure clamp (ATA4S-00)

  • Suffix Codes:

    • S = Standard type

    • 5 = No explosion protection

    • 0 = Basic type

  • Optional Code: /A4S00 = Supplied with pressure clamp terminal block

  • Mounting: Rack‑mounted (FIO subsystem)

  • Weight: Approx. 2.0 kg

  • Country of Origin: Japan

Application Scenarios

  • Integration into Yokogawa CENTUM VP and ProSafe‑RS systems

  • Process industries requiring reliable analog signal acquisition

  • Safety‑critical monitoring in petrochemical, oil & gas, and power generation

FAQ

Q: How many channels does the AAI143-S50/A4S00 support?  A: It supports 16 isolated analog input channels.

Q: What does the /A4S00 option mean?  A: It indicates the module is supplied with a pressure clamp terminal block (ATA4S-00).

Q: Is this module explosion‑proof?  A: No, the suffix “5” specifies that it is a non‑explosion protected type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more