PRODUCT SKU : 8200-1302

PRODUCT TYPE : Operator Panels

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for steam turbine management in 505D control platforms, the Woodward 8200-1302 (8200-1302 Operator Control Panel) provides direct physical/electrical execution of turbine HMI interaction, parameter configuration, and process monitoring.

Hardware Specifications

Parameter Specification
Model 8200-1302
Brand Woodward
Origin Not specified
Dimensions 8.4 in (LCD Screen)
Operating Temp -30 to 70 deg C
Power Consumption Not specified
Input Voltage 18-36 VDC (Isolated)
Analog Inputs 8 channels (4-20 mA compatible)
Enclosure Rating IP-54 (Marine / ATEX Compliant)

Actuator Loop Feedback Response

The 8200-1302 serves as the primary graphical interface for Woodward 505D governors, managing the communication and command flow required for stable turbine regulation. To ensure a predictable actuator loop feedback response, the unit processes dual redundant speed inputs—accepting signals from magnetic pickup units (MPUs), eddy current probes, or proximity probes—to compute precise speed control setpoints. The interface manages dual speed and load dynamics, allowing for optimized governor response during transient loading or frequency dead-band adjustments. The integration of 8 configurable analog inputs and 20 discrete contact inputs allows the controller to synthesize operational data into 4-20 mA control outputs, ensuring that the governor maintains setpoint integrity even under fluctuating process steam conditions.

Frequently Asked Questions

Q: Can the 8200-1302 communicate with external systems via standard industrial protocols?

A: Yes, the unit utilizes integrated Modbus communication ports for data exchange with external host controllers, SCADA systems, or auxiliary HMIs.

Q: Are the redundant speed inputs compatible with all probe types?

A: The dual redundant speed inputs are designed to accept a variety of sensing technologies, including passive magnetic pickup units (MPUs) and active eddy current or proximity probes. Ensure the sensor signal levels are within the input range of the 505D platform during commissioning.

Field Installation Guidelines

  1. Mounting: Secure the HMI in a panel cutout, ensuring the seal maintains the IP-54 rated ingress protection. Adhere to the Marine/ATEX compliance standards for physical clearance and grounding to prevent localized EMI.
  2. Wiring: Route 4-20 mA signal loops and contact inputs using shielded twisted-pair cabling. Separate these from high-power field cabling to avoid interference with the speed sensor acquisition circuits.
  3. Power Connection: Connect the unit to an isolated 18-36 VDC supply. Use proper surge protection to comply with EN 61000-6-2 electromagnetic immunity standards.
  4. Validation: After power-up, navigate to the calibration mode to verify the mapping of the 20 contact inputs and ensure the 8 analog inputs are correctly scaled for the turbine process variables. Confirm Modbus communication handshake before finalizing the configuration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more