Product Details
The 3500/94M VGA Display system integrates machinery protection data onto an external touch screen monitor. This specific listing covers the 190214-02 power-only I/O module, which is engineered to distribute power for front-mounted display configurations. It acts as a dedicated interface variant within the 3500 rack framework to support local operator touch screen visualization without standard serial loop wiring.
System Role and Power Delivery
The 190214-02 I/O module pairs with the 3500/94M main display module to supply the specialized power connections required by front-mounted display setups. It routes operational power through designated rear connectors while omitting standard auxiliary data loops. This layout simplifies physical wiring when the touch display is integrated directly onto the rack housing.
Rack Configuration and Compatibility
Operation of the 3500/94M display module requires a functioning 3500/22 Transient Data Interface (TDI) module within the rack to aggregate system values. The rack configuration software recognizes this power-only variant to correctly allocate system resources and manage screen interfaces. Technicians must verify that the chosen display mounting style matches the power distribution architecture of the 190214-02 hardware.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 3500/94M (190214-02) |
| Brand | Bently Nevada |
| Product Type | VGA Display I/O Module |
| Module Variant | Power-only I/O module for front-mount display |
| Dimensions (Height x Width x Depth) | 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) |
| Weight | 0.34 kg (0.75 lb) |
| Operating Temperature | -20 deg C to +65 deg C (-4 deg F to 149 deg F) |
| Storage Temperature | -40 deg C to +85 deg C (-40 deg F to 185 deg F) |
| Relative Humidity | 95%, noncondensing |
Frequently Asked Questions
Q: What is the specific purpose of the 190214-02 I/O module?
A: It is a power-only I/O module designed to supply power to a front-mounted touch screen display in a 3500 rack.
Q: Can the 190214-02 module be used interchangeably with the 190214-01 normal I/O module?
A: No, the 190214-02 lacks standard data communication interfaces and is strictly intended for power delivery to front-mount displays.
Q: What core rack module is required for the 3500/94M display system to operate?
A: The system requires a 3500/22 Transient Data Interface (TDI) module to process and supply data to the display driver.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.